600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2
Select gauge from drop-down menu for prices:
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01403
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01404
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01405
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01407
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01409
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01412
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01419
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01437
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01203
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01204
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01205
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01207
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01209
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01212
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01219
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01237
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01003
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01004
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 01009
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00803
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00804
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00603
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00604
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00403
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00404
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00203
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 00204
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 10103
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 10104
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 20103
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 20104
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 30103
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 30104
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 40103
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 40104
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 25003
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 25004
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 35003
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 35004
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 50003
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 50004
- 600 Volt UL Type MC-HL CT Use 90 XLP XHHW-2 - HW307 75003
Product Details
Specifications:
- Impervious Continuously Welded Armor - Power and Control Cable
- 600 Volt UL Type MC-HL, CT Use, 90°C
- XLP XHHW-2 Insulation
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Impervious armor prevents the entrance of water, gas and corrosive elements into the electrical core. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. UL listed, Type MC-HL per UL Standard 2225 for use in Class I, Division I hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).
Insulation:
Cross-linked polyethylene (XLP) per ICEA S-95-658 and UL Standard 44 for Type XHHW-2 conductors.
Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with NEC requirements.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Black flame-retardant and sunlight-resistant PVC.
Flame Tests:
- UL 1581 70,000 BTU/hr flame test
- ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
- IEEE 383 70,000 BTU/hr flame test
Color Code:
- 14 AWG - 10 AWG: ICEA Method 1, Table E-2
- 8 AWG - 750 kcmil: ICEA Method 4
Additional Standards:
- UL listed Type CWCMC to IEEE 45/IEEE 1580 (46 CFR Part 111.60-23) Marine Shipboard Cable.
- Meets requirements of CSA-C22.2 No. 0.3, -40°C cold impact test.
Connectors:
- Explosion Proof, Class I Division 1: 424MA series – all nickel-plated aluminum
- Rain Tight: 416MC series – all nickel-plated brass