General Cable ACWU90® 3C XLPE AIA PVC Low Voltage Power Armored 600V CSA
Select gauge from drop-down menu for prices:
- General Cable ACWU90® 3C 6 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 4 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 2 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 1 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 1/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 2/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 3/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 4/0 AWG XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 250MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 350MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 500MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 600MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
- General Cable ACWU90® 3C 750MCM XLPE AIA PVC Low Voltage Power Armored 600V CSA
Product Details
Conductor: 6 AWG thru 750 kcmil bare ACM aluminum (8000 series aluminum) compact Class B strand
Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 6 AWG to 2 AWG—black, white and red; 1/0 AWG to 750 kcmil—per ICEA Method 4, individual conductors colored black with conductor number surface printed in contrasting ink
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare aluminum (ACM) conductor
Armor: Aluminum Interlocked Armor (AIA)
Jacket: ACID-FLAME-CHECK ??® flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands
• For service entrance installations
Features:
• Rated at 90°C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40°C
Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 51 and No. 174
• CSA Approval File Number 157657
Flame Test Compliances: CSA FT1 and FT4
Other Compliances:
• Hazardous Location Rating: HL
• OSHA Acceptable
Packaging: For Canadian customers, nominal standard lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for cut to length, lagging and pulling eyes
cond. size (awg/ kcmil) |
cond. strand |
90?c amp** (30°c ambient) |
general cable part number |
Action |
6 | 7/.068 | 55 | 11281.030600 | Request A Quote |
4 | 7/.086 | 75 | 11281.030400 | Request A Quote |
2 | 7/.108 | 100 | 11281.030200 | Request A Quote |
1 | 8/.108 | 115 | 11281.030100 | Request A Quote |
1/0 | 10/.115 | 135 | 11281.035100 | Request A Quote |
2/0 | 12/.115 | 150 | 11281.035200 | Request A Quote |
3/0 | 16/.115 | 175 | 11281.035300 | Request A Quote |
4/0 | 19/.115 | 205 | 11281.035400 | Request A Quote |
250 | 23/.115 | 230 | 11281.036000 | Request A Quote |
350 | 26/.128 | 280 | 11281.036200 | Request A Quote |
500 | 37/.125 | 350 | 11281.036500 | Request A Quote |
600 | 61/.104 | 385 | 11281.036700 | Request A Quote |
750 | 61/.117 | 435 | 11281.037000 | Request A Quote |