Product Details
Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Beldenoffers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source.
Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.4572
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.5588
Applications: Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk.
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -30°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2092)
• Bulk Cable Weight: 17 lbs/1000 ft.
• Max. Recommended Pulling Tension: 16 lbs.
• Min. Bend Radius/Minor Axis: 1.750 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2092 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (µH/ft): 0.22
• Nom. Capacitance Conductor to Conductor (pF/ft): 16
• Nominal Velocity of Propagation (VP %): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 16
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
22 | 2 | 4.2672 | 8795 | Request A Quote |
22 | 3 | 4.521 | 8794 | Request A Quote |
22 | 4 | 5.080 | 9794 | Request A Quote |
22 | 4 | - | 1242A | Request A Quote |
22 | 2 | 4.318 | 8442 | Request A Quote |
22 | 3 | 4.3688 | 8443 | Request A Quote |
22 | 4 | 4.699 | 8444 | Request A Quote |
22 | 5 | 4.928 | 8445 | Request A Quote |
22 | 7 | 5.4356 | 9430 | Request A Quote |
22 | 8 | 5.8166 | 9421 | Request A Quote |
22 | 9 | 6.1976 | 9423 | Request A Quote |
22 | 10 | 6.706 | 8456 | Request A Quote |
22 | 12 | 6.9088 | 8457 | Request A Quote |
22 | 15 | 8.001 | 8458 | Request A Quote |
22 | 20 | 8.763 | 9431 | Request A Quote |
22 | 25 | 9.8298 | 8459 | Request A Quote |
22 | 30 | 10.160 | 9432 | Request A Quote |
22 | 40 | 11.557 | 9433 | Request A Quote |
22 | 50 | 12.700 | 9434 | Request A Quote |
22 | - | 2.591 | 88442 | Request A Quote |
22 | 4 | 3.073 | 88444 | Request A Quote |
22 | - | 2.870 | 82442 | Request A Quote |
22 | 4 | 3.4036 | 82444 | Request A Quote |