Helukabel Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable
Select gauge from drop-down menu for prices:
- Helukabel 8 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69601
- Helukabel 8 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69602
- Helukabel 6 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69603
- Helukabel 6 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69604
- Helukabel 4 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69605
- Helukabel 4 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69606
- Helukabel 2 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69607
- Helukabel 2 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69608
- Helukabel 1 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69609
- Helukabel 1 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69610
- Helukabel 2/0 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69611
- Helukabel 2/0 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69612
- Helukabel 3/0 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69613
- Helukabel 3/0 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69614
- Helukabel 4/0 AWG Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69615
- Helukabel 4/0 AWG Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69616
- Helukabel 250 MCM Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69617
- Helukabel 250 MCM Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69618
- Helukabel 350 MCM Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69619
- Helukabel 350 MCM Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69620
- Helukabel 450 MCM Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69621
- Helukabel 450 MCM Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69622
- Helukabel 550 MCM Green-Yellow Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69623
- Helukabel 550 MCM Black Color Single 602-RC-J/O Special Core Cable For Drag Chains 90C 600V Meter Marking Cable 69624
Product Details
Technical Data: Special PVC single core acc. to UL-Style 10107 and CSA AWM I/II AB, core acc. to DIN VDE 0285-525-2-31/ DIN EN 50525-2-31 (except 300 mm²)
Temperature Range:
• Flexing -5°C to +90°C
• Fixed installation -40°C to +90°C
Permissible Operating Temperature: Max. +90°C at conductor
Nominal Voltage:
• VDE U0/U 600/1000 V
• UL/CSA 600 V
Test Voltage: 4000 V
Breakdown Voltage: Min. 8000 V
Insulation Resistance: Min. 20 MOhm x km
Minimum Bending Radius:
• Flexing 7,5x cable Ø
• Fixed installation 3x cable Ø
Radiation Resistance: Up to 80x106 cJ/kg (up to 80 Mrad)
Cable Structure:
• Bare copper, extra fine wire conductors, to DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 and IEC 60228 cl.6, however by 185 mm² up to 300 mm² with reduced single wire-Ø, max. 0,30 mm
• Core insulation of special PVC compound type TI3 to DIN VDE 0207-363-3 / DIN EN 50363-3 and class 43, 90°C acc. to UL-Std.1581 colour black or green-yellow
• Outer sheath special PVC compound type YM5 to DIN VDE 0207 part 5 and class 43, 90°C acc. to UL-Std.1581
• Sheath colour black (RAL 9005)
• With meter marking
Properties:
• Chemical Resistance - see table Technical Informations
• Resistant to mineral oils, synthetic oils and lubricating coolants.
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) UL VW-1, CSA FT1
• Acc.to UL-Style 10107/ UL-Std.1581, CSA C22.2 No 210
Note:
• G = with green-yellow conductor
• x = without green-yellow conductor (OZ)
• 300 mm² in adaption
• AWG sizes are approximate equivalent values. The actual cross-section is in mm²
• Screened analogue type: Single 602-RC-CY-J/O
Application:
High flexible special single core cable for drag chains are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery manufacturer for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.