Skip to product information
1 of 1

Belden 16 AWG Triads Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

Belden 16 AWG Triads Individually and Overall Beldfoil Shielding UL Instrumentation 600V Tray Cable

SKU: SKU:  

Length: FT
Enter footage in the box - Cut to one length. Min 1 ft - Max 10000 ft.
Sold out
Shipping calculated at checkout.
Shipping Available
Free shipping on orders above $1000. *Wires and cables only.
View full details
Product Information

Product Details

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Inner Shield:
• Trade Name: Beldfoil®
• Type: Tape
• Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper

Outer Shield Drain Wire AWG:
• AWG: 16
• Stranding: 7x24
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.5435
• Outer Jacket Ripcord: Yes

Overall Cabling Lay Length and Direction:
• Length (in.): 7.000
• Twists (twist/ft): 1.710

Pair Lay Length and Direction:
• Lay Length (in.): 3.000
• Twists (twist/ft): 4.000

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 254.700 lbs/1000 ft.
• Max. Recommended Pulling Tension: 554 lbs.
• Min. Bend Radius/Minor Axis: 6.400 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.67
• Nom. Inner Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.99
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.07
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads overall cable-
nominal
dia. (mm)
belden cable
part number
Action
16 4 16.256 1097A Request A Quote
16 8 22.149 1098A Request A Quote
16 12 26.594 1099A Request A Quote
16 16 31.344 3118A Request A Quote
16 24 36.424 1100A Request A Quote
16 36 45.034 3130A Request A Quote
Reviews