Product Details
EPR Hypalon® 5KV Unshielded Type MV-90 Power Cable employs a Class B stranded copper conductor that bears ethylene propylene rubber insulation and a Hypalon® external jacket. The Class B stranded copper conductor is made of annealed uncoated copper. Annealed copper is often preferred because the process softens the metal making it more flexible and maneuverable. The outer jacket made of chlorosulfonated polyethylene (CSPE), better known as Hypalon®, is a synthetic rubber that protects the conductors from extreme temperatures, chemicals, and UV rays.
The MV-90 Power cable is designed to carry medium voltages up to 5,000 Volts. These cables are intended for use as a feeder and can be used in many different types of applications. EPR Hypalon® 5KV Unshielded Type MV-90 Power Cable can be installed in conduit, duct or aerial applications and must be supported by a messenger wire. This cable can also be buried directly, but only if it is installed in a system with a grounding conductor in close proximity. The cable can function in wet or dry locations and has a maximum conductor temperature of 90°C. Per Underwriters Laboratories specifications, this cable is deemed acceptable by the Occupational Safety and Health Administration (OSHA).
Size (AWG or KCMIL) |
Size AWG | Stranding | Diameter Complete Cable (O.D.) (Inches) | Weight Per 1000ft Total (Lbs.) | Allowable Ampacity Dwelling (Amps) |
6 Gauge 5kV EPR Hypalon MV-90 Non Shielded | 6 | 7 | .650 | 260 | 85 |
4 Gauge 5kV EPR Hypalon MV-90 Non Shielded | 4 | 7 | .700 | 330 | 110 |
2 Gauge 5kV EPR Hypalon MV-90 Non Shielded | 2 | 7 | .760 | 435 | 145 |
1 Gauge 5kV EPR Hypalon MV-90 Non Shielded | 1 | 19 | .800 | 506 | 170 |
1/0 5kV EPR Hypalon MV-90 Non Shielded | 1/0 | 19 | .840 | 590 | 195 |
2/0 5kV EPR Hypalon MV-90 Non Shielded | 2/0 | 19 | .880 | 700 | 220 |
3/0 5kV EPR Hypalon MV-90 Non Shielded | 3/0 | 19 | .960 | 860 | 250 |
4/0 5kV EPR Hypalon MV-90 Non Shielded | 4/0 | 19 | 1.020 | 1020 | 290 |
250MCM 5kV EPR Hypalon MV-90 Non Shielded | 250 | 37 | 1.140 | 1210 | 320 |
350MCM Gauge 5kV EPR Hypalon MV-90 Non Shielded | 350 | 37 | 1.240 | 1525 | 385 |
500MCM Gauge 5kV EPR Hypalon MV-90 Non Shielded | 500 | 37 | 1.370 | 2130 | 470 |
750MCM Gauge 5kV EPR Hypalon MV-90 Non Shielded | 750 | 61 | 1.620 | 3090 | 585 |