Prysmian and Draka Cable Dry FusionLink Armored Ribbon central tube Cable
Select gauge from drop-down menu for prices:
Product Details
Features and Benefits:
Compact Design:
• Efficient packaging of higher fiber counts
• Lightweight and easy to handle during installation
Easily Removable Ribbon Matrix:
• Allows for ease of stripping and fiber breakout
• Improves mid-span strippability
Precision Ribbon Geometry: Time and labor savings during fiber splicing
Flexible Buffer Tube:
• Superior kink resistance
• Increased flexibility
• Facilitates route management in closures
Dry Water-Blocking Technology:
• Buffer tube and core are completely dry—no gel
• Permits rapid cable preparation and termination
• Water-blocking materials are easily removed
ezPrep® Corrugated Steel Armor:
• Provides additional mechanical protection
• Special coating reduces time and effort to remove jacket
Available Uncoupled or Coupled Designs:
• Coupled design (RCD product >48F) couples the ribbon stack with the cable which elimates the need for splice point coupling coils in aerial application
• Un-coupled design (RCU product) requires the use of coupling coils at the splice points in aerial applications to prevent fiber retraction in closures
Performance:
• Meets or exceeds the requirements of Telcordia GR-20 & ICEA 640 and is tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
• Tested in accordance with relevant EIA/TIA-455 series FOTPs for fiber optic cables
• Complies with RUS PE-90
Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001
performance specifications | ||
bend radius dynamic static |
20 x cable od 10 x cable od |
|
tensile rating installation residual |
n 2700 800 |
lbf 600 180 |
crush resistance short/ long term |
n/cm 220/110 |
lbf/in 125/63 |
temperature ratings operation installation storage/shipping |
°c -40 to +70 -30 to +60 -40 to +75 |
°f -40 to +158 -22 to +140 -40 to +167 |
Nominal Design Parameters
fiber count |
ribbon count |
fibers/ ribbon |
aerial coupling coils required (rcd) |
aerial coupling coils required (rcu) |
buffer tube od | cable od | cable weight | max. length | ||||
(mm) | (inches) | (mm) | (inches) | (kg/km) | (lb/kft) | (m) | (ft) | |||||
12-48 | 1-4 | 12 | non available | yes | 6.2 | 0.24 | 12.5 | 0.50 | 152 | 102 | 11,187 | 36,693 |
60-72 | 5-6 | 12 | no | yes | 8.8 | 0.35 | 16.3 | 0.64 | 224 | 151 | 11,187 | 36,693 |
84-96 | 7-8 | 12 | no | yes | 9.5 | 0.37 | 17.0 | 0.67 | 233 | 157 | 10,095 | 33,111 |
108-144 | 9-12 | 12 | no | yes | 10.6 | 0.42 | 18.1 | 0.71 | 258 | 173 | 8,880 | 29,126 |
156-216 | 13-18 | 12 | no | yes | 12.3 | 0.48 | 19.8 | 0.78 | 285 | 192 | 7,580 | 24,862 |
240-432* | 10-18 | 24 | no | yes | 15.4 | 0.61 | 22.9 | 0.90 | 353 | 237 | 5,445 | 17,864 |