Product Details
Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Beldenoffers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.4318
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128
Overall Cabling Lay Length and Direction:
• Length (mm): 76.200
• Twists (twist/m): 13.124 (Left Hand Direction)
Applications: Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk.
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 60°C (UL AWM Style 2598)
• Bulk Cable Weight: 65.481 Kg/Km
• Max. Recommended Pulling Tension: 369.201 N
• Min. Bend Radius/Minor Axis: 69.850 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL3, CMG
• NEC Articles: 760, 800
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2598 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 85.306
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 20.6703
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4 Amps/Conductor @ 25°C ambient (10C Temp. Rise)
Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 88489, 82489
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
18 | 4 | 6.528 | 8489 | Request A Quote |
18 | 5 | 7.163 | 8465 | Request A Quote |
18 | 7 | 7.849 | 8467 | Request A Quote |
18 | 9 | 9.2456 | 8469 | Request A Quote |
18 | 12 | 10.465 | 8466 | Request A Quote |
18 | 15 | 12.700 | 8468 | Request A Quote |
18 | 19 | 12.446 | 8619 | Request A Quote |
18 | 25 | 15.545 | 9626 | Request A Quote |
18 | 4 | 3.962 | 88489 | Request A Quote |
18 | 4 | 4.216 | 82489 | Request A Quote |