ÖLFLEX® VFD 2XL is a robust oil- and UV-resistant shielded motor cable for VFD drives. The XLPE (plus) insulation with enhanced electrical properties can withstand twice the dielectric voltage test, provides extended performance, and is suitable for 2kV applications.
Construction
Conductors:
• finely stranded bare copper
Insulation:
• XLPE (plus)
Shielding:
• barrier tape; triple layer foil tape (100% coverage);tinned copper braid (85% coverage); tinned copper drain wire
Jacket:
• specially formulated thermoplastic elastomer (TPE); black
Technical data
Minimum bend radius:
• 7.5 x cable diameter
Temperature range:
• - UL/CSA TC: -25°C to +90°C
• - for stationary use: -40°C to +105°C
• - for flexible use: -25°C to +105°C
Nominal voltage:
• - UL TC: 600V/2000V
• - UL Flexible Motor Supply: 1000V
• - c(UL) CIC/TC: 600V
•- cRU AWM: 1000V
Test voltage:
• 6000V
Conductor stranding:
• - 16 - 6 AWG: Class 5 fine wire
• - 4 - 2 AWG: Class K fine wire
Color code:
• black with white numbers,plus green/yellow ground
Approvals:
• UL: UL: TC-ER per UL 1277
WTTC per UL 2277
AWM 20626
• Attributes: UL Oil Res I/II
90°C wet or dry
-40°C cold bend; -25°C cold impact
sunlight resistant
direct burial
NFPA 79
bus drop approval
• NEC: Class 1 Division 2 per NEC Article 501
• Canada: c(UL) CIC/TC FT4
cRU AWM I/II A/B FT4
• Additional: CE (50V – 1kV) & RoHS
Features
• One cable for applications up to 2kV
• Low capacitance design
• Industrial grade phthalate-free jacket designed for harsh environments.
• UL TC-ER & c(UL) CIC/TC approved
• Reduces space and weight in tray
•No conduit required due to TC-ER rating
AWG | Number of conductors | Nominal Outer Diameter |
Copper Weight (lbs/mft) |
Approx. Weight (lbs/mft) |
Part Number | |
inches | mm | |||||
16 AWG (1.5 mm²) | ||||||
16 | 4 + drain | 0.509 | 12.9 | 70 | 160 | 700700 |
14 AWG (2.5 mm²) | ||||||
14 | 4 + drain | 0.582 | 14.8 | 100 | 196 | 700701 |
12 AWG (4 mm²) | ||||||
12 | 4 + drain | 0.656 | 16.7 | 144 | 258 | 700702 |
10 AWG (6 mm²) | ||||||
10 | 4 + drain | 0.707 | 18.0 | 199 | 320 | 700703 |
8 AWG (10 mm²) | ||||||
8 | 4 + drain | 0.887 | 22.5 | 298 | 575 | 700704 |
6 AWG (16 mm²) | ||||||
6 | 4 | 1.022 | 25.9 | 518 | 885 | 700705 |
4 AWG (21 mm²) | ||||||
4 | 4 | 1.158 | 29.4 | 642 | 1055 | 700706 |
2 AWG (33.7 mm²) | ||||||
2 | 4 | 1.332 | 33.8 | 980 | 1460 | 700707 |