Power Cable - Unishield 15KV UL Type MV-105, 105°C Single Conductor, Shielded EPR Insulation, CPE Jacket 133% Insulation Level Copper Conductor

Power Cable - Unishield 15KV UL Type MV-105, 105°C Single Conductor, Shielded EPR Insulation, CPE Jacket 133% Insulation Level Copper Conductor

Select gauge from drop-down menu for prices:

Power Cable - Unishield 15KV UL Type MV-105, 105°C Single Conductor, Shielded EPR Insulation, CPE Jacket 133% Insulation Level Copper Conductor

Product Details

Specifications:

  • HW210
  • Power Cable - Unishield
  • 15KV UL Type MV-105, 105°C
  • Single Conductor, Shielded
  • EPR Insulation, CPE Jacket
  • 133% Insulation Level
  • Copper Conductor

Application:
For use in power circuits up to 15KV when installed in open air, conduit, duct, cable tray when CT rated, or direct buried in earth, in wet and dry locations. Used for critical applications in harsh and caustic environments in chemical plants, refineries, steel mills, industrial plants, commercial buildings, utility substations and generating stations. UL approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions.

Conductors:
Compact soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-496, with a semi-conducting conductor shield.

Insulation:
Ethylene propylene rubber (EPR) per ICEA S-97-682.

Shield:
Six (6) corrugated copper shield wires longitudinally embedded in an exterior semi-conducting CPE jacket per ICEA S-97-682.

Jacket:
Sunlight-resistant CPE per ICEA S-97-682 and UL Standard 1072.

Flame Tests:

  • IEEE 383 70,000 BTU/hr flame test – CT-listed sizes 1/0AWG and larger
  • IEEE1202 70,000 BTU/hr, CSA FT4 flame test
  • ICEA T-29-520 210,000 BTU/hr flame test

Additional Standards:

  • ICEA S-93-639
  • NEMA WC74
  • AEIC CS8

Note:

  • CT rated on sizes 1/0 AWG and larger.
Size (AWG
or kcmil)
No. of
Strands
Net Weight Overall Diameter
(Inches)
Drain Wire Size AWG Jacket
Thickness (Mils)
Conductor Diameter (Inches) Product Code
2 Gauge 7 501 0.94 19 80 0.27 HW210 00201 /
HW21000201
1/0 19 661 1.02 18 80 0.34 HW210 10101 /
HW21010101
2/0 19 769 1.07 18 80 0.38 HW210 20101 /
HW21020101
4/0 19 1079 1.17 18 80 0.48 HW210 40101 /
HW21040101
250 MCM 37 1232 1.24 17 80 0.53 HW210 25001 /
HW21025001
350 MCM 37 1613 1.33 17 85 0.62 HW210 35001 /
HW21035001
500 MCM 37 2149 1.46 17 85 0.72 HW210 50001 /
HW21050001
750 MCM 61 3064 1.67 16 100 0.91 HW210 75001 /
HW21075001
1000 MCM 61 3936 1.86 15 115 1.06 HW210 10001 /
HW21010001