Corning 288 to 432 Fiber Single and Multimode UltraRibbon Riser Gel-Free Cable
Select gauge from drop-down menu for prices:
- Corning 288TV7-14180D20 288 Fiber 50 µm Multimode UltraRibbon Riser Gel-Free Cable
- Corning 360TV7-14180D20 360 Fiber 50 µm Multimode UltraRibbon Riser Gel-Free Cable
- Corning 432TV7-14180D20 432 Fiber 50 µm Multimode UltraRibbon Riser Gel-Free Cable
- Corning 288EV7-14101D20 288 Fiber Singlemode UltraRibbon Riser Gel-Free Cable
- Corning 360EV7-14101D20 360 Fiber Singlemode UltraRibbon Riser Gel-Free Cable
- Corning 432EV7-14101D20 432 Fiber Singlemode UltraRibbon Riser Gel-Free Cable
Product Details
Corning UltraRibbon™ Riser Gel-Free Cables continue the innovative breakthrough in indoor cable technology with a new generation of high-fiber-count single tube cables. Providing up to 432 fibers in a rugged, compact design, the cable maximizes the use of critical duct space and can easily fit in 1.25-in inner duct. A specially formulated flame-retardant jacket allows this cable to be used in indoor general purpose horizontal and riser applications. The cable consists of a single buffer tube containing a stack of up to eighteen 24-fiber ribbons. The 24-fiber ribbons can be easily separated by hand into two 12-fiber ribbons. The 12-fiber ribbons have readily identifiable ribbon IDs, fiber colors, and precise geometries that result in excellent mass-splicing yields.
Features and Benefits
• Each 12-fiber ribbon individually numbered- Easy identification
• Precise fiber and ribbon geometries in a gel-free design- Excellent mass splicing yields
• Flame-retardant jacket- Rugged and durable
• Up to 432 fibers in a compact design- Easily fits in 1.25-in diameter inner duct
• Common installations- Indoor vertical riser and general purpose horizontal according to National Electrical Code® (NEC®) Article 770
General Specifications:
• Environment: Indoor
• Application: General Purpose Horizontal, Vertical Riser
• Cable Type: Ribbon
• Product Type: Distribution
• Flame Rating: Riser (OFNR)
Standards:
• Listings: National Electrical Code® (NEC®) OFNR
• Design Criteria: CSA FT-4
• Test Criteria: ANSI/ICEA S-83-596
Temperature Range:
• Storage: -40 °C to 70 °C (-40 °F to 158 °F )
• Installation: -10 °C to 60 °C (14 °F to 140 °F )
• Operation: -20 °C to 70 °C (-4 °F to 158 °F )
Mechanical Characteristics Cable:
• Max. Tensile Strength, Short-Term1320 N (300 lbf)
• Max. Tensile Strength, Long-Term400 N (90 lbf)
Chemical Characteristics:
• RoHS: Free of hazardous substances according to RoHS 2011/65/EU
fiber count | fiber category | min. bend radius | corning cable part number |
Action |
288 | 50 µm MM (OM3) | 201 mm | 288TV7-14180D20 | Request a Quote |
360 | 50 µm MM (OM3) | 207 mm | 360TV7-14180D20 | Request a Quote |
432 | 50 µm MM (OM3) | 215 mm | 432TV7-14180D20 | Request a Quote |
288 | Single-mode (OS2) | 201 mm | 288EV7-14101D20 | Request a Quote |
360 | Single-mode (OS2) | 207 mm | 360EV7-14101D20 | Request a Quote |
432 | Single-mode (OS2) | 215 mm | 432EV7-14101D20 | Request a Quote |