General Cable Teck90® 3C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

General Cable Teck90® 3C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

Select gauge from drop-down menu for prices:

General Cable Teck90® 3C XLPE PVC AIA PVC Control and Power Armored 1000 V CSA

Product Details

Conductor:
• 14 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8
• 6 AWG thru 1000 kcmil bare copper compact Class B strand

Insulation:
• Cross-linked Polyethylene (XLPE), Type RW90
• Color-coded: 14 AWG to 2 AWG—black, red and blue; 1 AWG to 1000 kcmil—printed numbers

Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor

Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Armor: Aluminum Interlocked Armor (AIA)

Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black

Options: Galvanized Steel Interlocked Armor (GSIA)

Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands

Features:
• Rated at 90?C wet or dry
• Excellent crush resistance, oil and chemical resistance
• Provides long service life
• Meets cold bend and impact tests at -40?C

Compliances:
Industry Compliances: CSA Standard C22.2 No. 131 and No. 174

Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)

Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant

Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

cond.
size
(AWG/
kcmil)
no.
of
cond.
ampacity**
(30?
cambient)
general
cable
part
number
Action
14 3 25 330520* Request A Quote
12 3 30 780260 Request A Quote
10 3 40 331120 Request A Quote
8 3 55 793200 Request A Quote
6 3 75 11288.010600 Request A Quote
4 3 95 11288.010400 Request A Quote
3 3 115 11288.010300 Request A Quote
2 3 130 11288.010200 Request A Quote
1 3 145 11288.010100 Request A Quote
1/0 3 170 11288.015100 Request A Quote
2/0 3 195 11288.015200 Request A Quote
3/0 3 225 11288.015300 Request A Quote
4/0 3 260 11288.015400 Request A Quote
250 3 290 11288.016000 Request A Quote
350 3 350 11288.016200 Request A Quote
500 3 430 11288.016500 Request A Quote
750 3 535 11270.891327 Request A Quote
1000 3 535 11288.017500* Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question