Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580.

Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.

Armor: Braided bronze in accordance with IEEE 1580.

Sheath: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.

Applications:
Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored & sheathed). The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). This product may be manufactured in an unarmored or armored and sheathed version.

Features/Ratings:
• Superior resistance to oil, abrasion, moisture, sunlight, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6/1 kV
• Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore

Approvals:
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR

Conductor Size TypeDesignation Prysmian And Draka
Cable Part Number
Action
AWG/ MCM
8 7.57 FPNBS-8 T26144 Request A Quote
6 12.5 FPNBS-6 T26145 Request A Quote
5 18.6 FPNBS-5 T26146 Request A Quote
4 21.5 FPNBS-4 T26147 Request A Quote
3 25.6 FPNBS-3 T26148 Request A Quote
2 30.7 FPNBS-2 T26149 Request A Quote
1 46.1 FPNBS-1 T26150 Request A Quote
1/0 56.3 FPNBS-1/0 T26151 Request A Quote
2/0 66.5 FPNBS-2/0 T26152 Request A Quote
3/0 92.1 FPNBS-3/0 T26153 Request A Quote
4/0 112.6 FPNBS-4/0 T26154 Request A Quote
262 133.0 FPNBS-262 T26155 Request A Quote
313 158.6 FPNBS-313 T26156 Request A Quote
373 189.3 FPNBS-373 T26157 Request A Quote
444 225.1 FPNBS-444 T26158 Request A Quote
535 271.2 FPNBS-535 T26159 Request A Quote
646 327.5 FPNBS-646 T26160 Request A Quote
777 393.8 FPNBS-777 T26161 Request A Quote