Select gauge from drop-down menu for prices:
- Helukabel 20 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16121
- Helukabel 20 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16122
- Helukabel 20 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16123
- Helukabel 20 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16124
- Helukabel 19 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16125
- Helukabel 19 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16126
- Helukabel 19 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16127
- Helukabel 19 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16128
- Helukabel 18 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16129
- Helukabel 18 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16130
- Helukabel 18 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16131
- Helukabel 18 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16132
- Helukabel 16 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16133
- Helukabel 16 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16134
- Helukabel 16 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16135
- Helukabel 16 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16136
- Helukabel 14 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16137
- Helukabel 14 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16138
- Helukabel 14 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16139
- Helukabel 14 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16140
- Helukabel 12 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16141
- Helukabel 12 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16142
- Helukabel 12 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16143
- Helukabel 12 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16144
- Helukabel 10 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16145
- Helukabel 10 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16146
- Helukabel 10 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16147
- Helukabel 10 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16148
- Helukabel 8 AWG 2 Cores Without GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16149
- Helukabel 8 AWG 3 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16150
- Helukabel 8 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16151
- Helukabel 8 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16152
- Helukabel 6 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16153
- Helukabel 6 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16154
- Helukabel 4 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16469
- Helukabel 4 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16155
- Helukabel 2 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16470
- Helukabel 2 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16156
- Helukabel 1 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16471
- Helukabel 1 AWG 5 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16119
- Helukabel 2/0 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16472
- Helukabel 3/0 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16473
- Helukabel 4/0 AWG 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16474
- Helukabel 300 MCM 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16247
- Helukabel 350 MCM 4 Cores With GN-YE Conductor GY-CY-JB Flexible Cu-Screened Transparent EMC-Preferred Type Meter Marking Cable 16319
Product Details
Technical Data:
• Special-PVC control cable adapted to DIN VDE 0285-525-2-51/DIN EN 50525-2-51
Temperature Range:
• flexing -15°C to +80°C
• fixed installation -40°C to +80°C
Nominal Voltage:
• up to 1,5 mm² U0/U 300/500 V
• from 2,5 mm² U0/U 450/750 V
Test Voltage: 4000 V
Breakdown Voltage: min. 8000 V
Insulation Resistance:
• min. 20 MOhm x km
Mutual Capacitance:
• acc. to different cross-sections 0,5 up to 2,5 mm²:
• core/core approx. 150 nF/km
• core/screen approx. 270 nF/km
Coupling Resistance:
• max. 250 Ohm/km
Minimum Bending Radius:
• flexing 10x cable Ø
• fixed installation 5x cable Ø
Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)
Cable Structure:
• Bare copper, fine wire conductors, bunch stranded to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC compound type Z 7225
• Core identification to JB/OB colour code
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay-length
• Inner sheath of PVC
• Tinned copper braided screen, approx. 85% coverage
• Outer sheath of special PVC
• Sheath colour transparent
• with meter marking
Properties:
• Extensively oil resistant, oil-/chemical resistance see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note:
• G = with green-yellow conductor x = without green-yellow conductor (OB).
• By 5 cores with VDE-Reg. No.
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Unscreened analogue type: JB-500, JB-750
Application:
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid. These cables are suitable for flexible use for medium mechanical stresses with free movements. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above application.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.