Belden Cable Foundation Fieldbus Cable
Select gauge from drop-down menu for prices:
- Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable
- Belden 123077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable
- Belden 133077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable
- Belden 3078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable
- Belden 123078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Aluminum Interlocked Armor Cable
- Belden 133078F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 Steel Interlocked Armor Cable
- Belden 3076F Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 123076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Aluminum Interlocked Armor Cable
- Belden 133076F Cable 18 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Steel Interlocked Armor Cable
- Belden 183076F Cable 18 AWG 1 Pair Foundation Fieldbus/ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Continuous Armor Cable
- Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable
- Belden 2100A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S3076NH Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1327A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2101A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1327NH Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1328A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2102A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1328NH Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1329A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2103A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1329NH Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1330A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2104A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1330NH Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1331A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2105A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1331NH Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1332A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2106A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1332NH Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1333A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2107A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden S1333NH Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 LSZH Jacket Cable
- Belden 1359A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket Cable
- Belden 2108A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket Cable
- Belden 1360A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2109A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1361A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2110A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1362A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2111A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1363A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2112A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1364A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2113A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1365A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2114A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1366A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2115A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1367A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 PVC Jacket Cable
- Belden 2116A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 2117A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 FR-PVC Jacket Cable
- Belden 1336A Cable 14 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x22 PVC Jacket Cable
- Belden 1337A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2118A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden 1338A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2119A Cable 18 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket 600V Cable
- Belden 1339A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus PA DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2120A Cable 18 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 FR-PVC Jacket 600V Cable
- Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2121A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1341A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2122A Cable 18 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1342A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2123A Cable 18 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1343A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2124A Cable 18 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden SI1344A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2125A Cable 18 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 TPE Jacket 600V Cable
- Belden 2126A Cable 18 AWG 50 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
- Belden 2127A Cable 16 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2128A Cable 16 AWG 2 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2129A Cable 16 AWG 5 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2130A Cable 16 AWG 8 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2131A Cable 16 AWG 12 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2132A Cable 16 AWG 16 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2133A Cable 16 AWG 20 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2134A Cable 16 AWG 24 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
- Belden 2135A Cable 16 AWG 36 Pairs Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x24 TPE Jacket Cable
Product Details
Get application flexibility in a variety of tough applications, including outdoors and where multiple cable runs are required. Belden cables are designed to withstand the destructive effects of temperature extremes, humidity/moisture, dust, and oil. With the high cost of downtime in industrial applilcations, it pays to invest in cables like Belden's fieldbus to ensure maximum protection and performance.
Insulation:
• Material: PO - Polyolefin
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Drain Wire Conductor Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 18 lbs/1000 ft.
• Max. Recommended Pulling Tension: 27 lbs.
• Min. Bend Radius/Minor Axis: 2.200 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM, ITC, PLTC
• NEC Articles: 725, 727, 800
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100
• Nom. Inductance (µH/ft): 0.19
• Nom. Capacitance Conductor to Shield (pF/ft): 45.0
• Nom. Mutual Capacitance (pF/ft): 24.0
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nominal Velocity of Propagation: VP (%): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm/1000 ft
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor
Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum(Y/N): No
Benefits:
• Maximum performance and durability
• Tightly integrated digital control
• Installation flexibility
Features:
• Rugged design, with multiple armor, shield, and rating options
• Unifield system architecture (HSE) for plant operations
• Designed to work in a varietly of applications, environments and conditions.