Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable

Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable

Select gauge from drop-down menu for prices:

Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable
Belden 1340A Cable 18 AWG 8 Pairs Foundation Fieldbus or ProfiBus PA DataBus Multi Conductor Stranded 7x26 PVC Jacket 600V Cable

Description:
• 18 AWG stranded (7x26) tinned copper conductors, ground wire, flame retardant polyolefin insulation, polyolefin fillers, inner and overall Beldfoil® shield (100% coverage), tinned copper drain wire, polypropylene separator, oil and sunlight resistant PVC jacket.

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 18
• Ground Wire Stranding: 7x26
• Ground Wire Conductor Material: TC - Tinned Copper
• Ground Wire Insulation Material: PVC - Polyvinyl Chloride

Insulation:
• Material: FRPO - Flame Retardant Polyolefin

Inner Shield:
• Type: Tape
• Inner Shield Material: Aluminum Foil-Polyester Tape

Inner Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Conductor Material: TC - Tinned Copper

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +75°C
• UL Temperature Rating: 75°C
• Max. Recommended Pulling Tension: 381 lbs.
• Min. Bend Radius/Minor Axis: 8.100 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 11/01/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100.000
• Nom. Inductance (μH/ft): 0.220
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 45.000
• Nom. Mutual Capacitance (pF/ft): 24.000
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.860
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm/1000 ft
• Max. Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor

Flame Test:
• UL Flame Test: UL1685 UL Loading

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 18
# pairs 8
stranding 7x26
no. of conductors 17
conductor material tinned copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum Foil-polyester tape
overall cable - nominal diameter (in.) 0.810
belden cable part number 1340A