Helukabel OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable
Select gauge from drop-down menu for prices:
- Helukabel 20 AWG 2 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14077
- Helukabel 20 AWG 3 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14078
- Helukabel 20 AWG 4 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14079
- Helukabel 20 AWG 6 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14080
- Helukabel 20 AWG 8 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14081
- Helukabel 20 AWG 10 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14082
- Helukabel 20 AWG 12 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14083
- Helukabel 20 AWG 16 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14084
- Helukabel 20 AWG 20 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14085
- Helukabel 20 AWG 24 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14086
- Helukabel 20 AWG 25 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14087
- Helukabel 19 AWG 2 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14089
- Helukabel 19 AWG 3 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14090
- Helukabel 19 AWG 4 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14091
- Helukabel 19 AWG 6 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14092
- Helukabel 19 AWG 8 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14093
- Helukabel 19 AWG 10 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14094
- Helukabel 19 AWG 12 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14095
- Helukabel 19 AWG 16 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14096
- Helukabel 19 AWG 20 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14097
- Helukabel 19 AWG 24 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14098
- Helukabel 19 AWG 25 Pairs OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable 14099
Product Details
Technical Data:
• Special PVC control cable with blue outer sheath for hazardous areas to hazard type -i- for intrinsically safe installation acc. to DIN EN 60079-14 and IEC 60079-14 section 12.2.2. (VDE 0165 part 1)
Conductor Resistance:
• at 0,5 mm² 37,8 Ohm/km
• at 0,75 mm² 25,3 Ohm/km
Temperature Range:
• flexing -10°C to +80°C
• fixed installation -30°C to +80°C
Operating Peak Voltage:
• (not for heavy current installation purposes) 900 V
Test Voltage:
• core/core 2000 V
• core/screen 1000 V
Breakdown Voltage: min. 4000 V
Insulation Resistance:
• min. 20 MOhm x km
Mutual Capacitance:
• core/core approx. 105 nF/km
• core/screen approx. 145 nF/km
Inductance:
• approx. 0,68 mH/km
Characteristic Impedance:
• approx. 80 Ohm
Coupling Resistance:
• max. 250 Ohm/km
Minimum Bending Radius:
• flexing 10x cable Ø
• fixed installation 5x cable Ø
Radiation resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)
Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification (pair) to DIN 47100
• Cores twisted in pairs
• Pairs stranded in layers with optimal lay-length
• Separating foil
• Tinned copper braided screen, approx. 85% coverage
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour blue (RAL 5015)
• With meter marking
Properties:
• Extensively oil resistant, oil-/chemical resistance see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note:
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Instrumentation cable RE-2Y(St)Yv with blue outer sheath see Data and Computer Cables
Application:
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part 12. 2. 2. 6, which covers the requirements for the special marking (blue) of this type (hazard type -i-). The paired construction and the copper screening afford a good protection against electrical interference and ensure the transmission of data signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
awg-no. | no.cores x cross-sec.mm² |
weight app. kg / km |
helukabel part number |
Action |
20 | 2 X 2 X 0,5 | 89,0 | 14077 | Request A Quote |
20 | 3 X 2 X 0,5 | 104,0 | 14078 | Request A Quote |
20 | 4 X 2 X 0,5 | 126,0 | 14079 | Request A Quote |
20 | 6 X 2 X 0,5 | 171,0 | 14080 | Request A Quote |
20 | 8 X 2 X 0,5 | 251,0 | 14081 | Request A Quote |
20 | 10 X 2 X 0,5 | 282,0 | 14082 | Request A Quote |
20 | 12 X 2 X 0,5 | 261,0 | 14083 | Request A Quote |
20 | 16 X 2 X 0,5 | 445,0 | 14084 | Request A Quote |
20 | 20 X 2 X 0,5 | 525,0 | 14085 | Request A Quote |
20 | 24 X 2 X 0,5 | 590,0 | 14086 | Request A Quote |
20 | 25 X 2 X 0,5 | 622,0 | 14087 | Request A Quote |
19 | 2 X 2 X 0,75 | 105,0 | 14089 | Request A Quote |
19 | 3 X 2 X 0,75 | 128,0 | 14090 | Request A Quote |
19 | 4 X 2 X 0,75 | 156,0 | 14091 | Request A Quote |
19 | 6 X 2 X 0,75 | 216,0 | 14092 | Request A Quote |
19 | 8 X 2 X 0,75 | 309,0 | 14093 | Request A Quote |
19 | 10 X 2 X 0,75 | 355,0 | 14094 | Request A Quote |
19 | 12 X 2 X 0,75 | 405,0 | 14095 | Request A Quote |
19 | 16 X 2 X 0,75 | 560,0 | 14096 | Request A Quote |
19 | 20 X 2 X 0,75 | 671,0 | 14097 | Request A Quote |
19 | 24 X 2 X 0,75 | 795,0 | 14098 | Request A Quote |
19 | 25 X 2 X 0,75 | 803,0 | 14099 | Request A Quote |