Helukabel OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable

Helukabel OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable

Select gauge from drop-down menu for prices:

Helukabel OB-BL-PAAR-CY Outer Sheath Blue Intrinsic Safety EMC-Preferred Type Meter Marking Cable

Product Details

Technical Data:
• Special PVC control cable with blue outer sheath for hazardous areas to hazard type -i- for intrinsically safe installation acc. to DIN EN 60079-14 and IEC 60079-14 section 12.2.2. (VDE 0165 part 1)

Conductor Resistance:
• at 0,5 mm² 37,8 Ohm/km
• at 0,75 mm² 25,3 Ohm/km

Temperature Range:
• flexing -10°C to +80°C
• fixed installation -30°C to +80°C

Operating Peak Voltage:
• (not for heavy current installation purposes) 900 V

Test Voltage:
• core/core 2000 V
• core/screen 1000 V

Breakdown Voltage: min. 4000 V

Insulation Resistance:
• min. 20 MOhm x km

Mutual Capacitance:
• core/core approx. 105 nF/km
• core/screen approx. 145 nF/km

Inductance:
• approx. 0,68 mH/km

Characteristic Impedance:
• approx. 80 Ohm

Coupling Resistance:
• max. 250 Ohm/km

Minimum Bending Radius:
• flexing 10x cable Ø
• fixed installation 5x cable Ø

Radiation resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification (pair) to DIN 47100
• Cores twisted in pairs
• Pairs stranded in layers with optimal lay-length
• Separating foil
• Tinned copper braided screen, approx. 85% coverage
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour blue (RAL 5015)
• With meter marking

Properties:
• Extensively oil resistant, oil-/chemical resistance see table Technical Informations
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)

Note:
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Instrumentation cable RE-2Y(St)Yv with blue outer sheath see Data and Computer Cables

Application:
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part 12. 2. 2. 6, which covers the requirements for the special marking (blue) of this type (hazard type -i-). The paired construction and the copper screening afford a good protection against electrical interference and ensure the transmission of data signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

awg-no. no.cores x
cross-sec.mm²
weight app.
kg / km
helukabel
part number
Action
20 2 X 2 X 0,5 89,0 14077 Request A Quote
20 3 X 2 X 0,5 104,0 14078 Request A Quote
20 4 X 2 X 0,5 126,0 14079 Request A Quote
20 6 X 2 X 0,5 171,0 14080 Request A Quote
20 8 X 2 X 0,5 251,0 14081 Request A Quote
20 10 X 2 X 0,5 282,0 14082 Request A Quote
20 12 X 2 X 0,5 261,0 14083 Request A Quote
20 16 X 2 X 0,5 445,0 14084 Request A Quote
20 20 X 2 X 0,5 525,0 14085 Request A Quote
20 24 X 2 X 0,5 590,0 14086 Request A Quote
20 25 X 2 X 0,5 622,0 14087 Request A Quote
19 2 X 2 X 0,75 105,0 14089 Request A Quote
19 3 X 2 X 0,75 128,0 14090 Request A Quote
19 4 X 2 X 0,75 156,0 14091 Request A Quote
19 6 X 2 X 0,75 216,0 14092 Request A Quote
19 8 X 2 X 0,75 309,0 14093 Request A Quote
19 10 X 2 X 0,75 355,0 14094 Request A Quote
19 12 X 2 X 0,75 405,0 14095 Request A Quote
19 16 X 2 X 0,75 560,0 14096 Request A Quote
19 20 X 2 X 0,75 671,0 14097 Request A Quote
19 24 X 2 X 0,75 795,0 14098 Request A Quote
19 25 X 2 X 0,75 803,0 14099 Request A Quote