Belden Cable 14 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable
Select gauge from drop-down menu for prices:
- Belden 8627 Cable 14 AWG 4 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x27 Non Plenum Cable
- Belden 9623 Cable 14 AWG 5 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x27 Non Plenum Cable
- Belden 8628 Cable 14 AWG 7 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x27 Non Plenum Cable
- Belden 8629 Cable 14 AWG 12 Conductors Audio Control and Instrumentation Multi Conductor Stranded 19x27 Non Plenum Cable
Product Details
Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Beldenoffers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 1.143
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.143
Applications: Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk.
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• Bulk Cable Weight: 205.372 Kg/Km
• Max. Recommended Pulling Tension: 845.158 N
• Min. Bend Radius/Minor Axis: 127 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 59.058
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 9.1868
• Max. Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 7.5 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: VW-1
• CSA Flame Test: FT1
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
14 | 4 | 12.446 | 8627 | Request A Quote |
14 | 5 | 14.554 | 9623 | Request A Quote |
14 | 7 | 15.824 | 8628 | Request A Quote |
14 | 12 | 20.9296 | 8629 | Request A Quote |