Helukabel (H)05VV5-F (N)YSLYÖ-JZ Flexible Number coded Oil Resistant, Meter Marking Cable

Helukabel (H)05VV5-F (N)YSLYÖ-JZ Flexible Number coded Oil Resistant, Meter Marking Cable

Select gauge from drop-down menu for prices:

Helukabel (H)05VV5-F (N)YSLYÖ-JZ Flexible Number coded Oil Resistant, Meter Marking Cable

Product Details

Technical data: 
• Spezial-PVC control cable with oil resistant outer sheath adapted to DIN VDE 0285-525-2-5 /DIN EN 50525-2-51 and IEC 60227/75 deviation of conductor cross sections 

Temperature range: 
• Flexing -5°C to +70°C 
• Fixed installation -40°C to +70°C 

Nominal voltage: U0/U 300/500 V 

Test voltage: 2 kV, 5 minutes 

Breakdown voltage: Min. 4000 V 

Insulation resistance: Min. 20 MOhm x km 

Minimum bending radius: 
• Flexing 7,5x cable Ø 
• Fixed installation 4x cable Ø 

Radiation resistance: 
• Up to 80x106 cJ/kg (up to 80 Mrad) 

Cable structure: 
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5 
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3 
• Core identification to DIN VDE 0293 black cores with continuous white numbering 
• GN-YE conductor, 3 cores and above in the outer layer 
• Cores stranded in layers with optimal lay-length 
• Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1 
• Sheath colour grey (RAL 7001) 
• with meter marking 

Properties: 
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers 

Tests: 
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) 
• Oil resistant to DIN EN 60811-404 

Note: 
• G = with green-yellow conductor x = without green-yellow conductor (OZ) 
• AWG sizes are approximate equivalent values. The actual cross-section is in mm². 
• Screened analogue type: (H)05VVC4V5-K 

Application: 
• These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in drymoist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines. These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

awg-no. no.cores x
cross-sec.mm²
weight app.
kg / km
helukabel
part number
Action
12 2 x 4 195,0 13133 Request A Quote
12 3 g 4 230,0 13134 Request A Quote
12 4 g 4 295,0 13135 Request A Quote
12 5 g 4 361,0 13136 Request A Quote
12 7 g 4 466,0 13138 Request A Quote
12 12 g 4 810,0 13141 Request A Quote
10 2 x 6 280,0 13142 Request A Quote
10 3 g 6 358,0 13143 Request A Quote
10 4 g 6 424,0 13144 Request A Quote
10 5 g 6 525,0 13145 Request A Quote
10 7 g 6 625,0 13146 Request A Quote
8 3 g 10 540,0 13148 Request A Quote
8 4 g 10 701,0 13149 Request A Quote
8 5 g 10 858,0 13150 Request A Quote
8 7 g 10 1106,0 13151 Request A Quote
6 3 g 16 827,0 13153 Request A Quote
6 4 g 16 1035,0 13154 Request A Quote
6 5 g 16 1259,0 13155 Request A Quote
6 7 g 16 1780,0 13156 Request A Quote
4 4 g 25 1582,0 13159 Request A Quote
4 5 g 25 1852,0 13160 Request A Quote
2 3 g 35 1614,0 13161 Request A Quote
2 4 g 35 2110,0 13162 Request A Quote
2 5 g 35 2652,0 13163 Request A Quote
1 3 g 50 2560,0 13164 Request A Quote
1 4 g 50 2972,0 13165 Request A Quote
1 5 g 50 3948,0 13166 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question