General Cable Type MC-HL 600V UL or Type ITC-HL 300V XLPE UL Armored Instrumentation Pairs Triads Individual and Overall Shield Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®

General Cable Type MC-HL 600V UL or Type ITC-HL 300V XLPE UL Armored Instrumentation Pairs Triads Individual and Overall Shield Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®

Select gauge from drop-down menu for prices:

General Cable Type MC-HL 600V UL or Type ITC-HL 300V XLPE UL Armored Instrumentation Pairs Triads Individual and Overall Shield Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®

Product Details

Conductor: 
• Bare annealed copper per ASTM B3
• Class B stranding per ASTM B8

Insulation: 
• Cross-linked Polyethylene (XLPE), rated 90°C per UL Standards 13 and 2250
• Color-coded per ICEA Method 1: pairs
– black and white; triads
– black, white and red. Each conductor in each pair or triad is printed alphanumerically for easy identification

Shielded Pair/Triad:
• Isolated and individually twisted pairs or triads with Flexfoil® aluminum/polyester tape shield providing  100% coverage
• Stranded tinned copper drain wire, two sizes smaller than insulated conductors

Cable Assembly:  Individually shielded pairs or triads are cabled together with a left-hand lay

Overall Shield:
• Flexifoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors

Inner Jacket:
• Flame retardant Polyvinyl Chloride (PVC) per UL Standard 1569, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -60°C
• Nylon rip cord to facilitate jacket removal

CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL Standards 1569 and 2225
• CCW armor conductivity meets the grounding requirements of NEC Article 250

Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standard 1569, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -60°C

Applications: 
• CCW armored 600 volt instrumentation cables with individually shielded pairs or triads and an overall shield provide superior protection and reliability against physical damage for use in instrumentation and process control applications where shielding against both external EMI and EMI between groups is required 
• For use in Class 1 remote-control and signal circuits in accordance with NEC Article 725 
• Recognized for use in Class I, II and III, Divisions 1 and 2; or Class 1, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505 
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial 
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

Features: 
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids 
• CCW armor provides EMI shielding performance 
• Meets cold bend at -55°C

Specifications:

Design Adherence: 
• UL 1569 Metal Clad Cables 
• UL 2225 Cables and Cable Fittings for Use in Hazardous Locations 
• UL 2250 Instrumentation Tray Cable 
• UL 1309/CSA C22.2 No. 245 Marine Shipboard Cable

Flame Tests: 
• ICEA T-29-520 (210,000 BTU/hr) 
• IEEE 383 (70,000 BTU/hr) 
• CSA FT4 
• IEEE 1202 (70,000 BTU/hr) 
• UL 1581 (70,000 BTU/hr) 
• IEC 60332-3 Cat. A

Compliances: 
• UL Type MC-HL, CT USE, SUN RES, DIR BUR, -60°C, UL File # E90496 
• UL Type ITC-HL, UL File # E177408 
• UL Listed Marine Shipboard, UL File # E85994 
• American Bureau of Shipping (ABS) Listed for CWCMC 
• RoHS Compliant


cond. Size (AWG) No. of pairs approximate Net weight General cable part number Action
Lbs/1000Ft Kg/Km
18 AWG 7W (0.82 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
18 2 307 457 9400.18020001 Request a Quote
18 4 448 667 9400.18040001 Request a Quote
18 6 551 820 9400.18060001 Request a Quote
18 8 609 906 9400.18080001 Request a Quote
18 10 774 1152 9400.18100001 Request a Quote
18 12 893 1329 9400.18120001 Request a Quote
18 16 1050 1562 9400.18160001 Request a Quote
18 20 1234 1836 9400.18200001 Request a Quote
18 24 1497 2228 9400.18240001 Request a Quote
18 36 1882 2800 9400.18360001 Request a Quote
18 50 2739 4076 9400.18500001 Request a Quote
16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED PAIRS
16 1 196 292 9400.16010001 Request a Quote
16 2 337 501 9400.16020001 Request a Quote
16 4 495 737 9400.16040001 Request a Quote
16 6 627 933 9400.16060001 Request a Quote
16 8 783 1165 9400.16080001 Request a Quote
16 10 955 1421 9400.16100001 Request a Quote
16 12 1061 1579 9400.16120001 Request a Quote
16 16 1274 1896 9400.16160001 Request a Quote
16 20 1576 2345 9400.16200001 Request a Quote
16 24 1725 2567 9400.16240001 Request a Quote
16 36 2436 3625 9400.16360001 Request a Quote
16 50 3361 5001 9400.16500001 Request a Quote


cond. Size (AWG) No. of pairs approximate Net weight General cable part number Action
Lbs/1000Ft Kg/Km
18 AWG 7W (0.82 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
18 2 337 501 9400.18020002 Request a Quote
18 4 495 737 9400.18040002 Request a Quote
18 8 785 1168 9400.18080002 Request a Quote
18 12 1062 1580 9400.18120002 Request a Quote
18 16 1322 1967 9400.18160002 Request a Quote
18 24 1806 2687 9400.18240002 Request a Quote
18 36 2525 3757 9400.18360002 Request a Quote
16 AWG 7W (1.31 mm²) INDIVIDUAL AND OVERALL SHIELDED TRIADS
16 1 207 308 9400.16010002 Request a Quote
16 2 429 638 9400.16020002 Request a Quote
16 4 564 839 9400.16040002 Request a Quote
16 8 928 1381 9400.16080002 Request a Quote
16 12 1300 1934 9400.16120002 Request a Quote
16 16 1654 2461 9400.16160002 Request a Quote
16 24 2348 3494 9400.16240002 Request a Quote
16 36 3319 4939 9400.16360002 Request a Quote