HW114 Thermocouple Extension Cable - EX JX KX TX 300 Volt UL Type PLTC & ITC, 200°C Single Pair Overall Shield FEP Teflon Insulation FEP Teflon Jacket Solid Alloy Conductor
Select gauge from drop-down menu for prices:
- HW114 Thermocouple Extension Cable - 300 Volt UL Type PLTC & ITC, 200°C Single Pair Overall Shield FEP Teflon® Insulation FEP Teflon® Jacket Solid Alloy Conductor - 16 AWG - 1 Pair - E X ANSI Type
- HW114 Thermocouple Extension Cable - 300 Volt UL Type PLTC & ITC, 200°C Single Pair Overall Shield FEP Teflon® Insulation FEP Teflon® Jacket Solid Alloy Conductor - 16 AWG - 1 Pair - J X ANSI Type
- HW114 Thermocouple Extension Cable - 300 Volt UL Type PLTC & ITC, 200°C Single Pair Overall Shield FEP Teflon® Insulation FEP Teflon® Jacket Solid Alloy Conductor - 16 AWG - 1 Pair - K X ANSI Type
- HW114 Thermocouple Extension Cable - 300 Volt UL Type PLTC & ITC, 200°C Single Pair Overall Shield FEP Teflon® Insulation FEP Teflon® Jacket Solid Alloy Conductor - 16 AWG - 1 Pair - T X ANSI Type
Product Details
Specifications:
- HW114
- Thermocouple Extension Cable - EX JX KX TX
- 300 Volt UL Type PLTC & ITC, 200°C
- Single Pair
- Overall Shield
- FEP Teflon® Insulation
- FEP Teflon® Jacket
- Solid Alloy Conductor
Application:
For use in high temperature thermocouple extension applications in caustic environments where protection from electrostatic interference is required. UL listed as Type PLTC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in NEC Class 1, Division 2 hazardous locations.
Conductors:
FEP Teflon® color coded per ANSI-MC96.1.
Insulation:
Flame-retardant ethylene propylene rubber (FR-EP) color coded per ANSI-MC96.1. Flame-retardant cross-linked polyethylene per ICEA S-66-524.
Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Jacket:
FEP Teflon® color coded per ANSI-MC96.1. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Flame Tests:
- UL Standard 13 70,000 BTU/hr flame test
- UL 910 Steiner tunnel flame test
- Meets CSA FT4/FT6 flame test
Additional Standards:
- NEC Type ITC per Articles 501, 502, 503, and 504
- UNEC Type CL3P/PLTC
Awg size | no. of pairs | Net Weight Lbs/Mft | Catalog Number | Action |
16 | 1 | 32 | HW114 1602E / HW1141602E |
Request a Quote |
16 | 1 | 31 | HW114 1602J / HW1141602J |
Request a Quote |
16 | 1 | 31 | HW114 1602K / HW1141602K |
Request a Quote |
16 | 1 | 32 | HW114 1602T / HW1141602T |
Request a Quote |