Product Details

Conductor:
• Bare annealed copper per ASTM B3
• Compressed Class B stranding per ASTM B8

Insulation:
• Cross-linked Polyethylene (XLPE) insulation per ICEA S-73-532 and UL 44, Listed XHHW-2
• Color-coded per ICEA Method 1, Table E2, full-colored insulation with stripes
• Color-coded per CSA C22.2 No. 123 where applicable

Grounding Conductor:
• Class B stranded bare annealed copper per ASTM B3 and B8
• Cross-linked Polyethylene (XLPE) insulation, green
• Sized in accordance with NEC Table 250.122

Cable Assembly:
• Insulated conductors and grounding wire are cabled together with non-hydroscopic fillers when required
• A binder tape, when required, is applied over the cabled core

CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL Standards 1569 and 2225
• CCW armor conductivity meets the grounding requirements of NEC Article 250

Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -60°C

Applications:
• CCW armored control cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
• For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• For use as services, feeders and branch circuits for power, lighting, control, and signal circuits in accordance with NEC Articles 330 and 725
• Installed indoors or outdoors, wet or dry locations, directly buried, embedded in concrete, in a raceway, as aerial cable on a messenger, in cable trays, or as exposed runs secured to supports in accordance with NEC Article 330
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

Features:
• CCW armor provides an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Factory assembled and tested cable for use as an alternate to cable in conduit wiring systems
• Meets cold bend at -55°C
• 90°C continuous operating temperature, wet or dry
• 130°C emergency rating
• 250°C short circuit rating

Specifications:
Design Adherence:
• ICEA S-73-532/WC57 Standard for Control, Thermocouple Extension and Instrumentation Cables
• UL 44 Rubber Insulated Wires and Cables
• UL 1569 Metal Clad Cables
• UL 2225 Cables and Cable Fittings for Use in Hazardous Locations
• UL 1309 Marine Shipboard Cable
• CSA C22.2 No. 123 Metal Sheathed Cables
• CSA C22.2 No. 174 Cables and Cable Glands for Use in Hazardous Locations

Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A

Compliances:
• UL Type MC-HL, XHHW-2, SUN RES, CT USE, DIR BUR, -40°C, UL File # E90496
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant

cond. Size (AWG) No. of cond. 90°c ampacity
@ 30°c ambient²
General cable part number Action
14 awg 7w (2.08 mm²) multi-conductor control cable with green insulated grounding conductor
14 2 15 9505.01402114 Request a Quote
14 3 15 9505.01403114 Request a Quote
14 3 15 9505.01403318 Request a Quote
14 4 15 9505.01404114 Request a Quote
14 4 15 9505.01404216 Request a Quote
14 5 15 9505.01405114 Request a Quote
14 6 15 9505.01406114 Request a Quote
14 8 15 9505.01408114 Request a Quote
14 11 12 9505.01411114 Request a Quote
14 18 12 9505.01418114 Request a Quote
14 36 10 9505.01436114 Request a Quote
12 awg 7w (3.31 mm²) multi-conductor control cable with green insulated grounding conductor
12 2 20 9505.01202112 Request a Quote
12 3 20 9505.01203112 Request a Quote
12 3 20 9505.01203316 Request a Quote
12 4 20 9505.01204112 Request a Quote
12 4 20 9505.01204316 Request a Quote
12 5 20 9505.01205112 Request a Quote
12 6 20 9505.01206112 Request a Quote
12 8 20 9505.01208112 Request a Quote
12 11 15 9505.01211112 Request a Quote
12 18 15 9505.01218112 Request a Quote
12 36 12 9505.01236112 Request a Quote
10 awg 7w (5.26 mm²) multi-conductor control cable with green insulated grounding conductor
10 2 30 9505.01002110 Request a Quote
10 3 30 9505.01003110 Request a Quote
10 3 30 9505.01003314 Request a Quote
10 4 30 9505.01004110 Request a Quote
10 4 30 9505.01004314 Request a Quote
10 6 28 9505.01006110 Request a Quote
10 8 28 9505.01008110 Request a Quote
10 11 20 9505.01011110 Request a Quote