Corning ALTOS® all-dielectric gel-free cables are designed for outdoor and limited indoor use for backbones in lashed aerial and duct installations. The loose tube gel-free design is fully waterblocked using craft-friendly, water-swellable materials, which means cable access is simple and no clean up is required. The flexible craft-friendly buffer tubes are easy to route in closures, and the SZ-stranded, loose tube design isolates fibers from installation and environmental rigors while allowing easy mid-span access. The all-dielectric cable construction requires no bonding or grounding, and these cables have a polyethylene jacket that is rugged, durable and easy to strip.
Features And Benefits:
• Gel-free waterblocking technology - Craft-friendly cable preparation
• Polyethylene jacket - Rugged, durable and easy to strip (while providing superior protection against UV radiation, fungus, abrasion and other environmental factors)
• All-dielectric construction - Requires no grounding or bonding
General Specifications:
• Environment: Outdoor
• Application: Aerial, Duct
• Cable Type: Loose Tube
• Product Type: Dielectric
• Fiber Category:50 µm MM (OM2)
Standards:
• Common Installations: Outdoor lashed aerial and duct; indoor when installed according to National Electrical Code® (NEC®) Article 770
• Design and Test Criteria: ANSI/ICEA S-87-640
Temperature Range:
• Storage: -40 °C to 70 °C (-40 °F to 158 °F )
• Installation: -30 °C to 70 °C (-22 °F to 158 °F )
• Operation: -40 °C to 70 °C (-40 °F to 158 °F )
Mechanical Characteristics Cable:
• Max. Tensile Strength, Short-Term: 2700 N (600 lbf)
• Max. Tensile Strength, Long-Term: 890 N (200 lbf)
• Nominal Outer Diameter: 10.5 mm (0.41 in)
• Min. Bend Radius Installation: 158 mm (6.2 in)
• Min. Bend Radius Operation: 105 mm (4.1 in)
Chemical Characteristics:
• RoHS: Free of hazardous substances according to RoHS 2011/65/EU