General Cable Type RA90 XLPE 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
Select gauge from drop-down menu for prices:
- General Cable Type RA90 XLPE 12Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 10 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 8 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 6 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 4 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 2 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 1 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 1/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 2/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 4/0 Gauge 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 250MCM 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 350MCM 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
- General Cable Type RA90 XLPE 500MCM 1000V Armored Power 3/C VFD CSA Cable Tray Use Sunlight-Resistant Direct Burial FT4 AG14 HL CCW®
Conductor:
• Bare annealed copper per ASTM B3
• Sizes 10 AWG and smaller are Class B compressed stranding per ASTM B8
• Sizes 8 AWG and larger are compact stranding per ASTM B496
Insulation:
• Cross-linked Polyethylene (XLPE) insulation rated 1000 Volts, RW90 per CSA C22.2 No. 38
• Sizes 2 AWG and smaller utilize a single color insulation: black, red and blue
• Sizes 1 AWG and larger utilize black insulation with printed number/color, 1-black, 2-red, 3-blue
Bonding/Grounding Conductors:
• Class B stranded bare annealed copper per ASTM B3 and B8
• Three (3) symmetrical grounding wires are sized in accordance with CEC Table 16
Cable Assembly:
• Three symmetrical grounding wires are cabled within the interstices of the phase conductors
• Non-hygroscopic fillers when required
• A binder tape is applied over the cabled core
CCW Armor: Impervious, continuously welded and corrugated aluminum alloy sheath per C22.2 No. 123
Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
• Meets CSA Low Gas Emission requirements, AG14
Applications:
• Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for use with AC motors controlled by pulse-width modulated inverters in VFD applications
• CCW armored cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
• For use in industrial and commercial installations including hazardous locations in accordance with the CEC
• Can be installed in wet or dry locations, indoors or outdoors, in cable trays, in a raceway, or direct buried in accordance with the CEC
Features:
• 90°C, 1000 V wet or dry XLPE insulation and three (3) symmetrical grounding wires, recommended for use with pulse-width modulated AC drives
• XLPE insulation has a dielectric constant less than 3.0 to withstand momentary voltage spikes common with VFD applications
• CCW armor provides an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Factory assembled and tested cable for use as an alternative to cable in conduit wiring systems
• Meets cold impact at -40°C
• 90°C continuous operating temperature, wet or dry
• 130°C emergency rating
• 250°C short circuit rating
Specifications:
Design Adherence:
• CSA C22.2 No. 38 Thermoset- Insulated Wires and Cables
• CSA C22.2 No. 123 Metal Sheathed Cables
• CSA C22.2 No. 174 Cables and Cable Glands for Use in Hazardous Locations
Flame Tests:
• CSA FT4
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr)
Compliances:
• CSA Certified Type RA90, XLPE, HL, SR, FT4, AG14 and -40°C, CSA File # 7319
• RoHS Compliant
cond. size (awg/ kcmil) | no. of cond. | 90° campacity @30°c ambient² | General Cable Part Number | Action |
12 (7/w) (3.31 mm²) |
3 | 30 | 9675.01203318 | Request A Quote |
10 (7/w) (5.26 mm²) |
3 | 40 | 9675.01003316 | Request A Quote |
8 (7/w) (8.36 mm²) |
3 | 55 | 9675.00803314 | Request A Quote |
6 (7/w) (13.3 mm²) |
3 | 75 | 9675.00603312 | Request A Quote |
4 (7/w) (21.2 mm²) |
3 | 95 | 9675.00403312 | Request A Quote |
2 (7/w) (33.6 mm²) |
3 | 130 | 9675.00203310 | Request A Quote |
(42.4 mm²) |
3 | 145 | 9675.00103310 | Request A Quote |
1/0 (19/w) (53.5 mm²) |
3 | 170 | 9675.11003310 | Request A Quote |
2/0 (19/w) (67.4 mm²) |
3 | 195 | 9675.21003310 | Request A Quote |
4/0 (19/w) (107 mm² |
3 | 260 | 9675.41003308 | Request A Quote |
250 (37/w) (127 mm²) |
3 | 290 | 9675.25003308 | Request A Quote |
350 (37/w) (177 mm²) |
3 | 350 | 9675.35003308 | Request A Quote |
500 (37/w) (253 mm²) |
3 | 430 | 9675.50003306 | Request A Quote |