Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 12
• Ground Wire Stranding: 7x20
• Conductor Material: BC - Bare Copper
• Insulation Material: Uninsulated

Insulation:
• Material: XLP - Cross Linked Polyolefin
• Nom. Wall Thickness (mm): 0.762

Inner Jacket:
• Material: PVC
• Nom. Wall Thickness (mm): 1.194
• Nom. Dia. (mm): 11.227

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket over Armor (y/n): Y

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.667

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C Wet/Dry
• Bulk Cable Weight: 413.720 Kg/Km
• Max. Recommended Pulling Tension: 728.401 N
• Min. Bend Radius/Minor Axis: 231.140 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2 #131; Hazardous Location; C22.2 #0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 3.37943
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 30 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
10 2 19.380 C5560 Request A Quote
10 3 - C5561 Request A Quote
10 4 21.082 C5562 Request A Quote
10 5 23.622 C5563 Request A Quote
10 6 - C5564 Request A Quote
10 7 25.146 C5565 Request A Quote
10 8 - C5566 Request A Quote
10 10 - C5568 Request A Quote
10 12 - C5570 Request A Quote
10 15 - C5573 Request A Quote
10 20 - C5578 Request A Quote
10 25 - C5579 Request A Quote
10 30 - C5580 Request A Quote