Skip to product information
1 of 1
Product Information

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.508

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 6.858

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Y

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 206.860 Kg/Km
• Max. Recommended Pulling Tension: 151.239 N
• Min. Bend Radius/Minor Axis: 173.990 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Max. Operating Voltage - Non-UL: 300 (CSA ACIC)

Flame Test:
• C(UL) Flame Test: FT4

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # triads belden cable
part number
Action
al. steel aluminum steel
20 20 1 23545 26539 Request A Quote
20 20 2 23546 26540 Request A Quote
20 20 4 23547 26541 Request A Quote
20 20 8 23548 26542 Request A Quote
20 20 12 23571 26553 Request A Quote
20 20 16 23549 26543 Request A Quote
20 20 24 23550 26544 Request A Quote
Reviews