Belden Cable 20 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Belden Cable 20 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Product Details

Belden® multi-conductor cables are manufactured in a wide variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions. These cables meet the technical requirements of many different types of systems. In fact, Beldenoffers one of the broadest lines of UL Listed, NEC and CEC multi-conductor cables available from any single source.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.381

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Applications: Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk.

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 30 lbs/1000 ft.
• Max. Recommended Pulling Tension: 50 lbs.
• Min. Bend Radius/Minor Axis: 2.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 27
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 10.7
• Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2464)
• Max. Recommended Current: 3.2 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
20 4 5.5118 9444 Request A Quote
20 5 6.071 9445 Request A Quote
20 7 6.604 9439 Request A Quote
20 9 8.0518 9455 Request A Quote
20 12 8.5852 9457 Request A Quote
20 15 9.8806 9458 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.