Prysmian and Draka Cable 8 AWG to 777 MCM Bostrig Type P Two Conductor Armored and Sheathed 600V Power Cable

Prysmian and Draka Cable 8 AWG to 777 MCM Bostrig Type P Two Conductor Armored and Sheathed 600V Power Cable

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable 8 AWG to 777 MCM Bostrig Type P Two Conductor Armored and Sheathed 600V Power Cable
Prysmian and Draka Cable 8 AWG to 777 MCM BOSTRIG TYPE P Two conductor armored and sheathed 600V Power Cable

Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.

Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580.

Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option. 

Armor: Braided bronze in accordance with IEEE 1580.

Sheath: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.

Applications:
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities.
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored and sheathed).
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version. 

Features and Ratings:
• Superior resistance to oil, abrasion, moisture, sunlight, crush and impact 
• High strand count conductors provide superior flexibility 
• Higher allowable conductor operating temperature results in increased ampacity 
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3 
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A 
• Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6/1 kV 
• Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore

Approvals:
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110 
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR

conductor
size
type
designation
prysmian and draka
cable part number
Action
awg/
mcm
mm2
8 7.57 dpnbs-8 T26108 Request A Quote
6 12.5 dpnbs-6 T26109 Request A Quote
5 18.6 dpnbs-5 T26110 Request A Quote
4 21.5 dpnbs-4 T26111 Request A Quote
3 25.6 dpnbs-3 T26112 Request A Quote
2 30.7 dpnbs-2 T26113 Request A Quote
1 46.0 dpnbs-1 T26114 Request A Quote
1/0 56.3 dpnbs-1/0 T26115 Request A Quote
2/0 66.5 dpnbs-2/0 T26116 Request A Quote
3/0 92.1 dpnbs-3/0 T26117 Request A Quote
4/0 112.6 dpnbs-4/0 T26118 Request A Quote
262 133.0 dpnbs-262 T26119 Request A Quote
313 158.6 dpnbs-313 T26120 Request A Quote
373 189.3 dpnbs-373 T26121 Request A Quote
444 225.1 dpnbs-444 T26122 Request A Quote
535 271.2 dpnbs-535 T26123 Request A Quote
646 327.5 dpnbs-646 T26124 Request A Quote
777 393.8 dpnbs-777 T26125 Request A Quote