Belden Plenum Rated EIA RS-232/422 Applications Paired Cable

Belden Plenum Rated EIA RS-232/422 Applications Paired Cable

Product Details

Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.

Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.

Insulation:
• Material: FFEP - Foam Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.381

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVDF - Fluorocopolymer
• Nom. Wall Thickness (mm): 0.356

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +150°C
• Bulk Cable Weight: 29.764 Kg/Km
• Max. Recommended Pulling Tension: 124.550 N
• Min. Bend Radius/Minor Axis: 57.150 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Inductance (µH/m): 0.68901
• Nom. Capacitance Conductor to Conductor (pF/m): 42.653
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 76.4473
• Nominal Velocity of Propagation (VP %): 78
• Nominal Delay (ns/m): 4.2653
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 78.744
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 50.8555
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.76 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
24 2 5.156 88102 Request A Quote
24 3 6.071 88103 Request A Quote
24 4 6.579 88104 Request A Quote
24 5 6.782 88105 Request A Quote
24 6 7.442 88106 Request A Quote
24 7 7.447 88107 Request A Quote
24 9 8.941 88109 Request A Quote
24 12 10.084 88112 Request A Quote
24 18 12.243 88118 Request A Quote
24 25 14.757 88125 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question