Superior Essex Cable ADSS 100 Series IF100 Cable
Select gauge from drop-down menu for prices:
- Superior Essex Cable 6 Fiber Count ADSS 100 Series IF100 Cable FE11-006XXX-E99Y
- Superior Essex Cable 12 Fiber Count ADSS 100 Series IF100 Cable FE11-012XXX-E99Y
- Superior Essex Cable 24 Fiber Count ADSS 100 Series IF100 Cable FE11-024XXX-E99Y
- Superior Essex Cable 48 Fiber Count ADSS 100 Series IF100 Cable FE11-048XXX-E99Y
- Superior Essex Cable 72 Fiber Count ADSS 100 Series IF100 Cable FE11-072XXX-E99Y
- Superior Essex Cable 96 Fiber Count ADSS 100 Series IF100 Cable FE11-096XXX-E99Y
- Superior Essex Cable 144 Fiber Count ADSS 100 Series IF100 Cable FE11-144XXX-E99Y
- Superior Essex Cable 216 Fiber Count ADSS 100 Series IF100 Cable FE11-216XXX-E99Y
- Superior Essex Cable 288 Fiber Count ADSS 100 Series IF100 Cable FE11-288XXX-E99Y
ADSS 100 is an All Dielectric Self Supporting (ADSS) cable suitable for aerial applications with span lengths from 60 meters to 160 meters depending on loading conditions and sag requirements. The exact span limit will vary depending on wind and loading conditions, sag requirements and other factors. This black, PE-jacketed cable is UV-stabilized and water blocked for outdoor aerial applications. The loose tube design provides stable and highly reliable transmission parameters for a variety of voice, data, video and imaging applications. The high modulus aramid yarns provide high tensile strength and long term reliability. Sag and tension charts are available.
Features:
• Available with up to 288-fiber
• Dry core standard
• Lower cost than Figure 8
• Energized installation
• Custom print
Benefits:
• High fiber density
• Reduces cable prep time
• Reduced network cost
• No downtime
• Personalization
Specifications:
Fiber Count: Available in 6-fiber up to 288-fiber
Compressive Strength lbs/in (N/cm):
• Install: 125 (220)
• Long Term: 63 (110)
Maximum Span NESC Loading District ft (m):
• Light: 492 (150)
• Medium: 328 (100)
• Heavy: 197 (60)
Recommended Hardware: FIBERLIGN® dead-end for ADSS Limited Tension
Standards Design and Test:
• ICEA S-87-640
• IEEE 1222
Environmental Specifications:
Operation/Storage: -40°C to +70°C
Installation: -30°C to +70°C
Applications:
• Low-voltage transmission and distribution system (space potential ≤12 kV)
• Railways, power and telecommunications pole routes
• Suitable for all type of aerial lines
fiber count | nominal diameter in (mm) | minimum bend radius | superior essex cable part number |
Action |
6 | 0.50 (12.6) | 5.0 (126) | FE11-006XXX-E99Y | Request a Quote |
12 | 0.50 (12.6) | 5.0 (126) | FE11-012XXX-E99Y | Request a Quote |
24 | 0.50 (12.6) | 5.0 (126) | FE11-024XXX-E99Y | Request a Quote |
48 | 0.50 (12.6) | 5.0 (126) | FE11-048XXX-E99Y | Request a Quote |
72 | 0.50 (12.6) | 5.0 (126) | FE11-072XXX-E99Y | Request a Quote |
96 | 0.53 (13.4) | 5.3 (134) | FE11-096XXX-E99Y | Request a Quote |
144 | 0.68 (17.2) | 6.8 (172) | FE11-144XXX-E99Y | Request a Quote |
216 | 0.68 (17.2) | 6.8 (172) | FE11-216XXX-E99Y | Request a Quote |
288 | 0.81 (20.5) | 8.1 (205) | FE11-288XXX-E99Y | Request a Quote |