General Cable Armored Instrumentation Pairs Triads XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Instrumentation 16 Gauge 1 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 2 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 4 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 8 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 12 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 16 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 24 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 36 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 50 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 1 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 2 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 4 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 8 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 12 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 16 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 24 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 36 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 50 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Product Details
Conductor:
• Bare annealed copper per ASTM B3
• Class B stranding per ASTM B8
Insulation:
• Cross-Linked Polyethylene (XLPE), rated 90°C per UL Standards 13 and 2250
• Color-coded per ICEA Method 1: pairs – black and white; triads – black, white and red. Each conductor in each pair or triad is printed alphanumerically for easy identification
Cable Assembly:
• Individual pairs or triads and communication wire are cabled together with a left hand lay
• Communication wire: 20 AWG solid bare copper, Cross-Linked Polyethylene (XLPE), rated 90°C, orange
• Communication wire is not included on single pair or single triad cables
Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors
Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacket removal
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requirements of NEC Article 250
Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
Applications:
• CCW armored Instrumentation cables with an overall shield provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC-HL or PLTC wiring methods where shielding against external EMI is required
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Recognized for use in Class I and III, Divisions 1 and 2; Class II, Division 2; or Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C
Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309 / CSA C22.2 No. 245 Marine Shipboard Cable
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A
Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC-HL, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant
cond. Size (AWG) | No. of pairs | approximate Net weight | General cable part number | Action | |
Lbs/1000Ft | Kg/Km | ||||
16 awg 7w (1.31 mm²) overall shielded pairs | |||||
16 | 1 | 207 | 308 | 9125.16010001* | Request a Quote |
16 | 2 | 307 | 457 | 9125.16021201 | Request a Quote |
16 | 4 | 390 | 580 | 9125.16041201 | Request a Quote |
16 | 8 | 632 | 941 | 9125.16081201 | Request a Quote |
16 | 12 | 857 | 1,275 | 9125.16121201 | Request a Quote |
16 | 16 | 1,081 | 1,609 | 9125.16161201 | Request a Quote |
16 | 24 | 1,431 | 2,130 | 9125.16241201 | Request a Quote |
16 | 36 | 1,933 | 2,877 | 9125.16361201 | Request a Quote |
16 | 50 | 2,550 | 3,795 | 9125.16501201 | Request a Quote |
16 awg 7w (1.31 mm²) overall shielded triads | |||||
16 | 1 | 235 | 350 | 9125.16010002* | Request a Quote |
16 | 2 | 441 | 656 | 9125.16021202 | Request a Quote |
16 | 4 | 569 | 847 | 9125.16041202 | Request a Quote |
16 | 8 | 859 | 1,278 | 9125.16081202 | Request a Quote |
16 | 12 | 1,207 | 1,796 | 9125.16121202 | Request a Quote |
16 | 16 | 1,424 | 2,119 | 9125.16161202 | Request a Quote |
16 | 24 | 2,103 | 3,130 | 9125.16241202 | Request a Quote |
16 | 36 | 2,659 | 3,957 | 9125.16361202 | Request a Quote |
16 | 50 | 3,800 | 5,655 | 9125.16501202 | Request a Quote |