General Cable Armored Instrumentation 16 Gauge 8 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Instrumentation Pairs Triads XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 1 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 2 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 4 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 8 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 12 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 16 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 24 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 36 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 50 Pair XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 1 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 2 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 4 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 12 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 16 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 24 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 36 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
- General Cable Armored Instrumentation 16 Gauge 50 Triad XLPE Overall Shield UL Type ITC-HL PLTC 300V Sunlight Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®
Conductor:
• Bare annealed copper per ASTM B3
• Class B stranding per ASTM B8
Insulation:
• Cross-Linked Polyethylene (XLPE), rated 90°C per UL Standards 13 and 2250
• Color-coded per ICEA Method 1: pairs – black and white; triads – black, white and red. Each conductor in each pair or triad is printed alphanumerically for easy identification
Cable Assembly:
• Individual pairs or triads and communication wire are cabled together with a left hand lay
• Communication wire: 20 AWG solid bare copper, Cross-Linked Polyethylene (XLPE), rated 90°C, orange
• Communication wire is not included on single pair or single triad cables
Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors
Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacket removal
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requirements of NEC Article 250
Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
Applications:
• CCW armored Instrumentation cables with an overall shield provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC-HL or PLTC wiring methods where shielding against external EMI is required
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Recognized for use in Class I and III, Divisions 1 and 2; Class II, Division 2; or Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C
Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309 / CSA C22.2 No. 245 Marine Shipboard Cable
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A
Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC-HL, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant
technical specifications: | |
cond. size (awg)
|
16 |
no. of pairs | 8 |
insulation thickness (mils) | 30 |
insulation thickness (mm) | 0.76 |
communication wire sizeawg | 20 |
communication wireins. thickness (mils) | 15 |
communication wireins. thickness (mm) | 0.38 |
inner jacket thickness(mils) | 109 |
inner jacket thickness (mm) | 2.77 |
nominal core o.d. (inches) | 1.04 |
nominal core o.d. (mm) | 26.4 |
nominal armor o.d. (inches) | 1.35 |
nominal armor o.d. (mm) | 34.3 |
jacket thickness (mils) | 50 |
jacket thickness (mm) | 1.27 |
nominal overall o.d.(inches)
|
1.46 |
nominal overall o.d. (mm) | 37.1 |
crosssectional area¹ (sq. in.) | 1.70 |
approximate size ins. thickness net weight(lbs/1000ft) | 859 |
approximate size ins. thickness net weight (kg/1000 m) | 1,278 |
catalog number | 9125.16081202 |