Helukabel JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable
Select gauge from drop-down menu for prices:
- Helukabel 20 AWG 2 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23314
- Helukabel 20 AWG 3 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23315
- Helukabel 20 AWG 3 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23316
- Helukabel 20 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23317
- Helukabel 20 AWG 4 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23318
- Helukabel 20 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23319
- Helukabel 20 AWG 5 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23320
- Helukabel 20 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23321
- Helukabel 20 AWG 7 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23322
- Helukabel 20 AWG 10 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23323
- Helukabel 20 AWG 12 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23324
- Helukabel 20 AWG 18 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23325
- Helukabel 20 AWG 25 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23326
- Helukabel 20 AWG 34 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23327
- Helukabel 20 AWG 42 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23328
- Helukabel 19 AWG 2 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23329
- Helukabel 19 AWG 3 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23330
- Helukabel 19 AWG 3 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23331
- Helukabel 19 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23332
- Helukabel 19 AWG 4 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23333
- Helukabel 19 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23334
- Helukabel 19 AWG 5 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23335
- Helukabel 19 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23336
- Helukabel 19 AWG 7 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23337
- Helukabel 19 AWG 10 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23338
- Helukabel 19 AWG 12 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23339
- Helukabel 19 AWG 18 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23340
- Helukabel 19 AWG 25 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23341
- Helukabel 19 AWG 34 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23342
- Helukabel 19 AWG 42 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23343
- Helukabel 18 AWG 2 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23344
- Helukabel 18 AWG 3 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23345
- Helukabel 18 AWG 3 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23346
- Helukabel 18 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23347
- Helukabel 18 AWG 4 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23348
- Helukabel 18 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23349
- Helukabel 18 AWG 5 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23350
- Helukabel 18 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23351
- Helukabel 18 AWG 7 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23352
- Helukabel 18 AWG 10 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23353
- Helukabel 18 AWG 12 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23354
- Helukabel 18 AWG 18 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23355
- Helukabel 18 AWG 25 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23356
- Helukabel 18 AWG 34 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23357
- Helukabel 18 AWG 42 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23358
- Helukabel 18 AWG 50 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23359
- Helukabel 16 AWG 2 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23360
- Helukabel 16 AWG 3 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23361
- Helukabel 16 AWG 3 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23362
- Helukabel 16 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23363
- Helukabel 16 AWG 4 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23364
- Helukabel 16 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23365
- Helukabel 16 AWG 5 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23366
- Helukabel 16 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23367
- Helukabel 16 AWG 7 Cores Without GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23368
- Helukabel 16 AWG 12 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23369
- Helukabel 16 AWG 18 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23370
- Helukabel 16 AWG 25 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23371
- Helukabel 16 AWG 30 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23372
- Helukabel 14 AWG 2 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23373
- Helukabel 14 AWG 3 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23374
- Helukabel 14 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23375
- Helukabel 14 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23376
- Helukabel 14 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23377
- Helukabel 14 AWG 12 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23378
- Helukabel 12 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23379
- Helukabel 12 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23380
- Helukabel 12 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23381
- Helukabel 10 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23382
- Helukabel 10 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23383
- Helukabel 10 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23384
- Helukabel 8 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23385
- Helukabel 8 AWG 5 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23386
- Helukabel 8 AWG 7 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23387
- Helukabel 6 AWG 4 Cores With GN-YE Conductor JZ-500 PUR Tear and Coolant Resistant Meter Marking Cable 23388
Product Details
Technical data:
• Special-PUR control cable adapted to DIN VDE 0285-525-1 / DIN EN 50525-1
Temperature range:
• Flexing -15°C to +80°C
• Fixed installation -40°C to +80°C
Nominal voltage:
• U0/U 300/500 V
Test voltage:
• 4000 V
Breakdown voltage:
• Min. 8000 V
Insulation resistance:
• Min. 20 MOhm x km
Minimum bending radius:
• Flexing 7,5x cable Ø
• Fixed installation 4x cable Ø
Radiation resistance:
• Up to 100x106 cJ/kg (up to 100 Mrad)
Cable structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5,
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3/ DIN EN 50363-3
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay-length
• Outer sheath of special full-polyurethane compound type TMPU to DIN EN 50363-10-2
• Sheath colour grey (RAL 7001) also available in other colours
• With meter marking
Properties:
• Resistant to UV-Radiation, Oxygene, Ozone and Hydrolysis, Microbes
• Low adhesion, matt surface
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: JZ-500-FC-PUR
Application:
• JZ-500 PUR is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance coolant emulsions, it is especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.