Prysmian and Draka Cable Type THW Polyvinyl chloride single conductor 14 AWG to 500 MCM Insulated 600V Wire
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable 14 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 12 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 10 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 6 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 8 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 4 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 2 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 1/0 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 2/0 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 4/0 AWG Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 250 MCM Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 350 MCM Type THW Polyvinyl chloride single conductor Insulated 600V Wire
- Prysmian and Draka Cable 500 MCM Type THW Polyvinyl chloride single conductor Insulated 600V Wire
Product Details
Conductors: Class B, soft drawn, bare copper per ASTM B3 and ASTM B8. Both tinned copper conductors and extra-flexible conductors are available as options.
Insulation: Heat and moisture resistant polyvinyl chloride (PVC) meeting the requirements of ICEA S-95-658 (NEMA WC 90) UL 83 for Type THW and wires. The insulation is suitable for use in wet or dry locations at a conductor temperature not exceeding 75° C for normal operation.
Assembly: Single conductor cables can be paralleled or multiplexed for more efficient installations. Single conductor cables can also be pre-installed in conduit.
Applications: Draka’s Type THW cable is suitable for various commercial and industrial applications. These cables may be installed in wet or dry locations, indoors or outdoors, in raceways, underground ducts (ask about our preinstalled cable-in-conduit products), aerial or direct buried. Draka’s Type THW cable is NEC-compliant for continuous operations at 75° C in wet and dry locations.
Specifications and Ratings:
• UL Type THW
• The insulation is suitable for use in wet or dry locations at a temperature not exceeding 75° C
• RoHS compliant
• Oil resistant I
• CT USE (#1/0 AWG and larger)
conductor size awg (mm²) |
strand class |
nominal cable o.d.in (mm) |
approximate cable weight lbs/mft (kg/km) |
Action |
14 awg (2.08) | class b | 0.140 (3.6) | 18 (27) | Request A Quote |
12 awg (3.31) | class b | 0.160 (4.1) | 28 (42) | Request A Quote |
10 awg (5.26) | class b | 0.180 (4.6) | 42 (63) | Request A Quote |
8 awg (8.37) | class b | 0.250 (6.3) | 69 (103) | Request A Quote |
6 awg (13.3) | class b | 0.310 (7.9) | 110 (164) | Request A Quote |
4 awg (21.2) | class b | 0.360 (9.1) | 165 (246) | Request A Quote |
2 awg (33.6) | class b | 0.420 (10.7) | 250 (373) | Request A Quote |
1/0 awg (53.5) | class b | 0.540 (13.7) | 400 (597) | Request A Quote |
2/0 awg (67.4) | class b | 0.580 (14.7) | 500 (746) | Request A Quote |
4/0 awg (107) | class b | 0.690 (17.5) | 755 (1126) | Request A Quote |
250 MCM (127) | class b | 0.770 (19.6) | 900 (1342) | Request A Quote |
350 MCM (177) | class b | 0.870 (22.1) | 1235 (1842) | Request A Quote |
500 MCM (253) | class b | 1.000 (25.4) | 1725 (2573) | Request A Quote |