General Cable Armored Power Shielded 25kV 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
Select gauge from drop-down menu for prices:
- General Cable Armored Power Shielded 25kV 1 Gauge 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power Shielded 25kV 1/0 Gauge 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power Shielded 25kV 2/0 Gauge 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power Shielded 25kV 4/0 Gauge 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power Shielded 25kV 250MCM 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power 25kV 350MCM 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
- General Cable Armored Power 25kV 500MCM 3/C UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®
Product Details
Conductor:
• Bare annealed copper per ASTM B3
• Compact stranding per ASTM B496
Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072
Insulation: 260 mils Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072
Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072
Shield: 5 mil annealed bare copper tape with 25% overlap
Phase Identification: Color-coded polymeric identification tape laid under the shield - black, red and blue
Grounding Conductor:
• Class B stranded bare annealed copper grounding conductor
• Sized in accordance with UL 1072 and NEC Article 250
Cable Assembly:
• Insulated and grounding conductors are cabled together with nonhygroscopic fillers when required
• Binder tape is applied over the cabled core
CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and UL 1569
• CCW armor conductivity meets the grounding requirements of the NEC
Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL 1072, orange
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
Applications:
• CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
• For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330
• For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart
• Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute
Features:
• CCW armor provides an impervious barrier to moisture, gas and liquids and meets the grounding requirements of UL 1072 and the NEC
• Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation
• General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress
• Cable meets cold impact at -40°C
• 105°C continuous operating temperature, wet or dry
• 140°C emergency rating
• 250°C short circuit rating
Specifications:
Design Adherence:
• ICEA S-93-639/WC74, 5-46 kV Shielded Power Cable
• AEIC CS8 Specification for Shielded Power Cable, 5-46 kV
• UL 1072 Medium-Voltage Power Cables
• UL 1569 Metal Clad Cables
• UL 2225 Cables and Cable Fittings for Use in Hazardous Locations
• UL 1309 Marine Shipboard Cable
• CSA 68.10
Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1072
• IEC 60332-3 Category A
Compliances:
• UL Type MV-105 or MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501
• UL Listed Marine Shipboard, UL File # E85994
• CSA Type HL, SR, FT4, -40°C, CSA File # 27161
• American Bureau of Shipping (ABS) Listed for CWCMC
cond. size | no. of cond. | ampacitydirect burial² | general cable part number | Action |
awg (kcmil) | ||||
1 (19/W) (42.4 mm²) |
3 | 225 | 9845.00103104 | Request a Quote |
1/0 (19/W) (53.5 mm²) |
3 | 255 | 9845.11003104 | Request a Quote |
2/0 (19/W) (67.4 mm²) |
3 | 290 | 9845.21003104 | Request a Quote |
4/0 (19/W) (107 mm²) |
3 | 345 | 9845.41003103 | Request a Quote |
250 (37/W) (127 mm²) |
3 | 410 | 9845.25003102 | Request a Quote |
350 (37/W) (177 mm²) |
3 | 495 | 9845.35003102 | Request a Quote |
500 (37/W) (253 mm²) |
3 | 590 | 9845.50003101 | Request a Quote |