Belden Cable Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor Paired Cable
Select gauge from drop-down menu for prices:
- Belden 88741 Cable 22 AWG 2 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor FEP Jacket Cable
- Belden 88757 Cable 22 AWG 4 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor FEP Jacket Cable
- Belden 82741 Cable 22 AWG 2 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor Flamarrest Jacket Cable
- Belden 82742 Cable 22 AWG 3 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor Flamarrest Jacket Cable
- Belden 82757 Cable 22 AWG 4 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor Flamarrest Jacket Cable
- Belden 82743 Cable 22 AWG 6 Pairs Unshielded Plenum Rated Audio Control and Instrumentation Multi Conductor Flamarrest Jacket Cable
Product Details
Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.
Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.178
Outer Jacket:
• Material: FEP - Fluorinated Ethylene Propylene
• Nom. Wall Thickness (mm): 0.229
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -70°C To +200°C
• Bulk Cable Weight: 23.811 Kg/Km
• Max. Recommended Pulling Tension: 80.068 N
• Min. Bend Radius/Minor Axis: 44.450 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 88
• Nom. Inductance (µH/m): 0.49215
• Nom. Capacitance Conductor to Conductor (pF/m): 55.777
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 52.496
• Nominal Conductor Loop Resistance @ 20°C (Ohm/km): 104.992
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.3 Amps/Conductor @ 25°C (10°C rise in temp)
Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 8741
awg | # pairs | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
22 | 2 | 4.293 | 88741 | Request A Quote |
22 | 4 | 5.080 | 88757 | Request A Quote |
22 | 2 | 4.547 | 82741 | Request A Quote |
22 | 3 | 4.851 | 82742 | Request A Quote |
22 | 4 | 5.334 | 82757 | Request A Quote |
22 | 6 | 6.045 | 82743 | Request A Quote |