General Cable EmPowr® 35 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

General Cable EmPowr® 35 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

EmPowr 35 kV Copper Wire PVC Jacket Fill Shielded Power Cable Al Conductor EPR Insulation

Complete Cable: Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper wires (helically applied), separator tape and overlaying black PVC jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-97- 682 and AEIC CS8 as applicable for Ethylene Propylene Rubber (EPR) insulated shielded power cable. 

Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum. 

Conductor Shield: Extruded semi-conducting thermosetting polymeric stress control layer. 

Insulation: Extruded Ethylene Propylene Rubber (EPR) Class II and III. 

Insulation Shield: Extruded semi-conducting thermosetting layer, clean and free stripping from insulation. 

Copper Wire Shield: Helically applied annealed solid bare copper wires with a lapped non-metallic tape serving as a binder/separator. 

Jacket: Black, non-conducting, sunlight-resistant Polyvinyl Chloride (PVC). 

Features and Benefits: 
• Triple-extruded for clean interfaces 
• Class 10,000 environment utilized for cable core material handling 
• Flexibility for easy handling 
• Excellent moisture resistance 
• Deformation-resistant 
• High dielectric strength 
• Low dielectric loss 
• Excellent resistance to water treeing 
• Clean-stripping insulation shield without the use of a release agent 
• Sunlight-resistant 

Temperature Rating: 
• Normal - 105°C 
• Emergency* - 140°C 
• Short Circuit - 250°C

Applications: EmPowr® Fill cables are intended for use in dry or wet locations for distribution of three-phase medium-voltage power. These cables may be installed in ducts or direct buried. 

Options: 
• Copper conductors 
• EmPowr® Fill LF Lead-Free EAM 
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 
• Dry nitrogen cure 
• True Triple Extrusion 
• 3 X 1/C triplex or parallel 
• Type MV-105 UL 1072 
• UL Listedb

compressed conductor copper neutral approx. weight (1) lb/1000 ft ampacity (2) Action
al awg/ kcmil wire size awg total in duct
1/0 22 784 170 Request a Quote
2/0 22 845 190 Request a Quote
3/0 22 918 220 Request a Quote
4/0 22 1007 250 Request a Quote
250 22 1088 275 Request a Quote
350 22 1268 340 Request a Quote
500 20 1615 410 Request a Quote
750 20 2017 525 Request a Quote
1000 20 2385 615 Request a Quote