XHHW HYP Tray Cable-With Hypalon Jacket Type TC

XHHW HYP Tray Cable-With Hypalon Jacket Type TC

Select gauge from drop-down menu for prices:

XHHW HYP Tray Cable-With Hypalon Jacket Type TC

Product Details

Conductors:
Coated annealed copper.
ASTM B-33 and B-189.
Concentric stranded class B (7 strands).
ASTM B-8, UL-44 paragraph 12.4 and UL-62 paragraph 10.2 (A suitable separator is applied between the conductor and insulation to facilitate stripping).

Insulation:
VW-1 crooslinked polyethylene (thermoset)

Cabling:
Three or more conductors are assembled round with flame resistant, non-hygroscopic and non-wicking neoprene fillers as needed. A flame resistant, non-hygroscopic and non-wicking tape binder is applied over the assembly. Two conductors are assembled flat parallel (round with neoprene fillers as needed, is available upon request).

Overall Jacket:
Heavy duty, flame and sunlight resistant hypalon® (black) (thermoset)

Color Coding:
ICEA Method 1 using solid colors with stripes in accordance with Table K-2

Scope:
This specification covers multiconductors having stranded coated copper conductors flame resistant crosslinked polyethlene insulation and a heavy duty flame and sunlight resistant Hypalon jacket. Cables conform to Article 318 cable trays and Article 340 power and control cable. Type TC of the 1984 NEC subject 1277 of underwriters laboratories Inc. and ICEA S-66-524, and meet the requirements of the 70,000 BTU cable tray propagation test per IEEE-383 cables are rated 600 volts 90°C dry and wet. Size 14, 12 and 10 AWG conductors are XHHW rated (VW-1). Also meets IEEE-1202, ICEA 1-29-520, T30-520 and FT-4.

Applications:
UL listed and OSHA acceptable.
Recognized for use in Class 1, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts, conduit and aerially where supported by a messenger.
Specifically approved for direct burial, wet and dry locations and outdoors in cable trays where a sunlight resistant rating is required.
Designed for control, power, lighting, telemetering, signal and relay or traffic control where a low loss high temperature insulation is specified.

Size
(AWG or kcmil)
Number of Conductors Diameter Complete Cable
(O.D.) (Inches)
Weight Per 1000 ft. (lbs.) Action
XHHW 16 Gauge 2 .339 58 Request a Quote
XHHW 16 Gauge 3 .357 79 Request a Quote
XHHW 16 Gauge 4 .389 101 Request a Quote
XHHW 16 Gauge 5 .425 116 Request a Quote
XHHW 16 Gauge 6 .462 137 Request a Quote
XHHW 16 Gauge 7 .462 147 Request a Quote
XHHW 16 Gauge 8 .567 171 Request a Quote
XHHW 16 Gauge 9 .590 194 Request a Quote
XHHW 16 Gauge 10 .621 205 Request a Quote
XHHW 16 Gauge 12 .682 243 Request a Quote
XHHW 16 Gauge 15 .738 294 Request a Quote
XHHW 16 Gauge 19 .760 357 Request a Quote
XHHW 16 Gauge 20 .866 372 Request a Quote
XHHW 16 Gauge 24 .877 460 Request a Quote
XHHW 16 Gauge 25 .891 480 Request a Quote
XHHW 16 Gauge 26 .950 506 Request a Quote
XHHW 16 Gauge 30 .950 570 Request a Quote
XHHW 16 Gauge 36 1.024 656 Request a Quote
XHHW 16 Gauge 37 1.024 671 Request a Quote
XHHW 14 Gauge 2 .367 73 Request a Quote
XHHW 14 Gauge 3 .387 109 Request a Quote
XHHW 14 Gauge 4 .423 123 Request a Quote
XHHW 14 Gauge 5 .462 129 Request a Quote
XHHW 14 Gauge 6 .504 158 Request a Quote
XHHW 14 Gauge 7 .576 176 Request a Quote
XHHW 14 Gauge 8 .602 230 Request a Quote
XHHW 14 Gauge 9 .617 257 Request a Quote
XHHW 14 Gauge 10 .643 279 Request a Quote
XHHW 14 Gauge 12 .677 381 Request a Quote
XHHW 14 Gauge 15 .746 415 Request a Quote
XHHW 14 Gauge 19 .808 545 Request a Quote
XHHW 14 Gauge 20 .872 573 Request a Quote
XHHW 14 Gauge 24 .946 668 Request a Quote
XHHW 14 Gauge 25 .958 691 Request a Quote
XHHW 14 Gauge 26 .974 708 Request a Quote
XHHW 14 Gauge 30 1.039 801 Request a Quote
XHHW 14 Gauge 36 1.122 916 Request a Quote
XHHW 14 Gauge 37 1.122 940 Request a Quote
XHHW 12 Gauge 2 .407 90 Request a Quote
XHHW 12 Gauge 3 .403 144 Request a Quote
XHHW 12 Gauge 4 .471 184 Request a Quote
XHHW 12 Gauge 5 .546 233 Request a Quote
XHHW 12 Gauge 6 .594 259 Request a Quote
XHHW 12 Gauge 7 .594 286 Request a Quote
XHHW 12 Gauge 8 .642 316 Request a Quote
XHHW 12 Gauge 9 .689 335 Request a Quote
XHHW 12 Gauge 10 .719 363 Request a Quote
XHHW 12 Gauge 12 .758 446 Request a Quote
XHHW 12 Gauge 15 .877 563 Request a Quote
XHHW 12 Gauge 19 .948 735 Request a Quote
XHHW 12 Gauge 20 .82 647 Request a Quote
XHHW 12 Gauge 24 .93 768 Request a Quote
XHHW 12 Gauge 25 .94 796 Request a Quote
XHHW 12 Gauge 26 .96 822 Request a Quote
XHHW 12 Gauge 30 1.02 938 Request a Quote
XHHW 12 Gauge 37 1.1 1134 Request a Quote
XHHW 10 Gauge 2 .455 127 Request a Quote
XHHW 10 Gauge 3 .482 185 Request a Quote
XHHW 10 Gauge 4 .559 246 Request a Quote
XHHW 10 Gauge 5 .611 309 Request a Quote
XHHW 10 Gauge 7 .666 333 Request a Quote
XHHW 10 Gauge 8 .686 362 Request a Quote
XHHW 10 Gauge 9 .722 406 Request a Quote
XHHW 10 Gauge 10 .810 539 Request a Quote
XHHW 10 Gauge 12 .856 673 Request a Quote
XHHW 10 Gauge 15 .906 789 Request a Quote
XHHW 10 Gauge 19 1.068 953 Request a Quote
XHHW 10 Gauge 20 1.10 999 Request a Quote
XHHW 10 Gauge 24 1.198 1217 Request a Quote
XHHW 10 Gauge 25 1.214 1260 Request a Quote
XHHW 10 Gauge 26 1.34 1314 Request a Quote
XHHW 10 Gauge 30 1.321 1525 Request a Quote
XHHW 10 Gauge 36 1.430 1844 Request a Quote
XHHW 10 Gauge 37 1.435 1901 Request a Quote