Belden 16 AWG CSA Control 600V ACIC 7x24 Armored Unshielded Cable

Belden 16 AWG CSA Control 600V ACIC 7x24 Armored Unshielded Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Ground Wire:
• Ground Wire (Y/N): Y
• Ground Wire AWG: 16
• Ground Wire Stranding: 7x24
• Conductor Material: BC - Bare Copper

Insulation:
• Material: XLPE - Cross Linked Polyethylene

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.636
• Outer Jacket over Armor (y/n): Y

Outer Jacket over Armor:
• Outer Jacket Material over Armor (y/n): PVC - Polyvinyl Chloride

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
• Diameter over Armor: 0.54

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -40°C To +90°C
• Dry Temperature Range: -40°C To +90°C
• Non-UL Temperature Rating: 90°C Wet/Dry
• Bulk Cable Weight: 300.616 Kg/Km
• Max. Recommended Pulling Tension: 275.788 N
• Min. Bend Radius/Minor Axis: 195.580 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, HAZ LOC, C22.2#0.3 Clause 4.31 Low Acid Gas
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 13.7802
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 10 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors overall cable-
nominal dia. (mm)
belden cable
part number
Action
16 2 16.510 29017 Request A Quote
16 3 16.764 29004 Request A Quote
16 4 17.780 29018 Request A Quote
16 5 18.542 29019 Request A Quote
16 6 19.558 29005 Request A Quote
16 7 19.558 29020 Request A Quote
16 8 20.320 29021 Request A Quote
16 10 23.368 29022 Request A Quote
16 12 23.876 29006 Request A Quote
16 15 25.400 29023 Request A Quote
16 20 28.702 29007 Request A Quote
16 25 32.004 29024 Request A Quote
16 30 33.020 29008 Request A Quote
16 40 35.814 29009 Request A Quote
16 50 39.116 29016 Request A Quote
16 60 42.164 29025 Request A Quote