Belden Cable Fire Alarm Power Limited Fire Protective Signaling Circuit Multi Conductor Cable
Select gauge from drop-down menu for prices:
- Belden 9576 Cable 22 AWG 6 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9571 Cable 18 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9574 Cable 18 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9578 Cable 18 AWG 4 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9572 Cable 16 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9575 Cable 16 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9579 Cable 16 AWG 4 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9580 Cable 14 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9581 Cable 14 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
- Belden 9582 Cable 12 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Multi Conductor Solid Cable
- Belden 9583 Cable 12 AWG 2 Conductors Power Limited Fire Protective Signaling Circuit Solid BC PVC Jacket Cable
Product Details
Description:
• 22 AWG solid TC conductors, conductors cabled, PVC insulation, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.3302
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9906
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -40°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 49.111 Kg/Km
• Max. Recommended Pulling Tension: 253.547 N
• Min. Bend Radius/Minor Axis: 63.500 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, FPLR
• NEC Articles: 760
• CEC/C(UL) Specification: FAS105
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: California State Fire Marshall
Electrical Characteristics (Overall):
• Nom. Inductance (µH/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 83.6655
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 52.496
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 3.5 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # conductors | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
22 | 6 | 5.944 | 9576 | Request A Quote |
18 | 2 | 5.791 | 9571 | Request A Quote |
18 | 2 | 5.867 | 9574 | Request A Quote |
18 | 4 | 6.680 | 9578 | Request A Quote |
16 | 2 | 6.045 | 9572 | Request A Quote |
16 | 2 | 6.121 | 9575 | Request A Quote |
16 | 4 | 7.645 | 9579 | Request A Quote |
14 | 2 | 7.696 | 9580 | Request A Quote |
14 | 2 | 7.772 | 9581 | Request A Quote |
12 | 2 | 8.636 | 9582 | Request A Quote |
12 | 2 | 8.712 | 9583 | Request A Quote |