General Cable VERTITECK® HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
Select gauge from drop-down menu for prices:
- General Cable VERTITECK® 2 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 1 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 1/0 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 2/0 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 3/0 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 4/0 AWG HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 250MCM HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 350MCM HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 500MCM HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
- General Cable VERTITECK® 750MCM HVTECK 3C 220 Mils TRXLPE Tape Shield PVC GSIA PVC Power Shielded Armored 15kV CSA
Product Details
Conductor: 2 AWG thru 750 kcmil bare copper compact Class B strand
Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor
Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)
Insulation Shield:
• This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
• Color code: black, red, or blue colored tape placed longitudinally under the copper tape shield
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor
Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Armor: Galvanized Steel Interlocked Armor (GSIA)
Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
• For wiring in all hazardous locations when used with certified HL cable glands
• Cost-effective alternative to installation in conduit
• Typical vertical installations include mine shafts, tall commercial buildings, inclined tunnels and vertical cable trays
(Note that the overall jacket is required for all damp and wet locations and for all corrosive environments: CE Code Part 1, Rules 12-708 and 22-200)
Features:
• Rated at 90?C wet or dry
• The jacket under the armor (inner jacket) is designed with longitudinal raised ribs. The armor is then applied and bites into these ribs to provide a solidly locked construction. This feature enables the cable to be self-supporting (core will not slip) during vertical installation when cable weight is supported by the copper conductors
• Lighter than mine shaft cable with conventional steel wire armor (SWA)
• More flexible than SWA cables, resulting in easier handling during installation
• Terminations and connections to electrical cabinets are similar to standard TECK90 cables
• Meets cold bend and impact tests at -40?C
Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 131 and No. 174
• CSA Standard C68.10
Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
• ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
cond. size (awg/ kcmil) |
no. of cond. | max. self supporting length** (m) |
general cable part number |
Action |
2 | 3 | 85 | 17497.540200* | Request A Quote |
1 | 3 | 100 | 17497.540100* | Request A Quote |
1/0 | 3 | 118 | 17497.545100* | Request A Quote |
2/0 | 3 | 137 | 17497.545200* | Request A Quote |
3/0 | 3 | 155 | 17497.545300* | Request A Quote |
4/0 | 3 | 176 | 17497.545400* | Request A Quote |
250 | 3 | 188 | 17497.546000* | Request A Quote |
350 | 3 | 215 | 17497.546200* | Request A Quote |
500 | 3 | 250 | 17497.546500* | Request A Quote |
750 | 3 | 277 | 17497.547000* | Request A Quote |