General Cable Armored Thermocouple Pairs Overall Shield UL Type ITC HL PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

General Cable Armored Thermocouple Pairs Overall Shield UL Type ITC HL PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Select gauge from drop-down menu for prices:

General Cable Armored Thermocouple Pairs Overall Shield UL Type ITC HL PLTC PVC Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Product Details

Conductor: 20 AWG solid alloy wire per ANSI MC 96.1

Insulation:
• Flame-retardant Polyvinyl Chloride (PVC), rated 105°C per UL Standards 13 and 2250
• Color-coded per ANSI with one conductor in each pair printed alphanumerically for easy identification

Cable Assembly:
• Individual pairs and communication wire are cabled together with a lefthand lay
• Communication wire: 22 AWG solid bare copper, flame-retardant Polyvinyl Chloride (PVC), rated 105°C, orange

Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors

Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250
• ANSI color-coded
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacket removal

CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requierments of NEC Article 250

Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250
• ANSI color-coded
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

Applications:
• CCW armored Thermocouple Extension cables provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC-HL or PLTC wiring methods
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Recognized for use in Class I and III, Divisions 1 and 2; Class II, Division 2 or Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C

Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309/CSA C22.2 No. 245 Marine Shipboard Cable

Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A

Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC-HL, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant

wire type Size (AWG) No. of pairs approximate Net weight General cable part number Action
Lbs/1000Ft Kg/Km
20 awg type ex multiple pairs overall shielded thermocouple extension cable
ex / 20 4 255 379 9050.20041221 Request a Quote
ex / 20 8 351 522 9050.20081221 Request a Quote
ex / 20 10 463 689 9050.20101221 Request a Quote
ex / 20 12 490 729 9050.20121221 Request a Quote
ex / 20 16 550 818 9050.20161221 Request a Quote
ex / 20 20 638 949 9050.20201221 Request a Quote
ex / 20 24 783 1,165 9050.20241221 Request a Quote
ex / 20 36 1,010 1,503 9050.20361221 Request a Quote
ex / 20 50 1,290 1,920 9050.20501221 Request a Quote
20 awg type jx multiple pairs overall shielded thermocouple extension cable
jx / 20 4 253 377 9050.20041222 Request a Quote
jx / 20 8 348 518 9050.20081222 Request a Quote
jx / 20 10 459 683 9050.20101222 Request a Quote
jx / 20 12 485 722 9050.20121222 Request a Quote
jx / 20 16 549 817 9050.20161222 Request a Quote
jx / 20 20 630 938 9050.20201222 Request a Quote
jx / 20 24 774 1,152 9050.20241222 Request a Quote
jx / 20 36 997 1,484 9050.20361222 Request a Quote
jx / 20 50 1,271 1,891 9050.20501222 Request a Quote
20 awg type kx multiple pairs overall shielded thermocouple extension cable
kx / 20 4 255 379 9050.20041223 Request a Quote
kx / 20 8 351 522 9050.20081223 Request a Quote
kx / 20 10 463 689 9050.20101223 Request a Quote
kx / 20 12 490 729 9050.20121223 Request a Quote
kx / 20 16 549 817 9050.20161223 Request a Quote
kx / 20 20 637 948 9050.20201223 Request a Quote
kx / 20 24 782 1,164 9050.20241223 Request a Quote
kx / 20 36 1,008 1,500 9050.20361223 Request a Quote
kx / 20 50 1,287 1,915 9050.20501223 Request a Quote
20 awg type tx multiple pairs overall shielded thermocouple extension cable
tx / 20 4 257 382 9050.20041224 Request a Quote
tx / 20 8 354 527 9050.20081224 Request a Quote
tx / 20 10 467 695 9050.20101224 Request a Quote
tx / 20 12 495 737 9050.20121224 Request a Quote
tx / 20 16 556 827 9050.20161224 Request a Quote
tx / 20 20 646 961 9050.20201224 Request a Quote
tx / 20 24 792 1,179 9050.20241224 Request a Quote
tx / 20 36 1,023 1,522 9050.20361224 Request a Quote
tx / 20 50 1,309 1,948 9050.20501224 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question