Belden IMSA Spec 20-1 Aerial and Duct 600V Signal Cable
Select gauge from drop-down menu for prices:
- Belden 582015 18 AWG 5 Conductors Spec 20-1 Stranded Signal Cable
- Belden 582024 16 AWG 2 Conductors Spec 20-1 Solid Signal Cable
- Belden 581761 16 AWG 7 Conductors Spec 20-1 Stranded Signal Cable
- Belden 582021 16 AWG 20 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601140 14 AWG 2 Conductors Spec 20-1 Solid Signal Cable
- Belden 601194 14 AWG 2 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601141 14 AWG 3 Conductors Spec 20-1 Solid Signal Cable
- Belden 601195 14 AWG 3 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601142 14 AWG 4 Conductors Spec 20-1 Solid Signal Cable
- Belden 601196 14 AWG 4 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601143 14 AWG 5 Conductors Spec 20-1 Solid Signal Cable
- Belden 601197 14 AWG 5 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601144 14 AWG 6 Conductors Spec 20-1 Solid Signal Cable
- Belden 603131 14 AWG 6 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601145 14 AWG 7 Conductors Spec 20-1 Solid Signal Cable
- Belden 601198 14 AWG 7 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601146 14 AWG 8 Conductors Spec 20-1 Solid Signal Cable
- Belden 601610 14 AWG 8 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601147 14 AWG 9 Conductors Spec 20-1 Solid Signal Cable
- Belden 601429 14 AWG 9 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601148 14 AWG 10 Conductors Spec 20-1 Solid Signal Cable
- Belden 601199 14 AWG 10 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601150 14 AWG 12 Conductors Spec 20-1 Solid Signal Cable
- Belden 601200 14 AWG 12 Conductors Spec 20-1 Stranded Signal Cable
- Belden 580307 14 AWG 14 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601153 14 AWG 15 Conductors Spec 20-1 Solid Signal Cable
- Belden 601331 14 AWG 15 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601154 14 AWG 16 Conductors Spec 20-1 Solid Signal Cable
- Belden 601201 14 AWG 16 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601157 14 AWG 19 Conductors Spec 20-1 Solid Signal Cable
- Belden 601454 14 AWG 19 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601158 14 AWG 20 Conductors Spec 20-1 Solid Signal Cable
- Belden 601202 14 AWG 20 Conductors Spec 20-1 Stranded Signal Cable
- Belden 603870 14 AWG 21 Conductors Spec 20-1 Solid Signal Cable
- Belden 582020 14 AWG 21 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601594 14 AWG 25 Conductors Spec 20-1 Solid Signal Cable
- Belden 581694 14 AWG 26 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601411 12 AWG 2 Conductors Spec 20-1 Solid Signal Cable
- Belden 601210 12 AWG 2 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601412 12 AWG 3 Conductors Spec 20-1 Solid Signal Cable
- Belden 601211 12 AWG 3 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601417 12 AWG 4 Conductors Spec 20-1 Solid Signal Cable
- Belden 601467 12 AWG 4 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601322 12 AWG 5 Conductors Spec 20-1 Solid Signal Cable
- Belden 601325 12 AWG 5 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601186 12 AWG 7 Conductors Spec 20-1 Solid Signal Cable
- Belden 601326 12 AWG 7 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601475 12 AWG 9 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601518 12 AWG 10 Conductors Spec 20-1 Solid Signal Cable
- Belden 601316 12 AWG 10 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601188 12 AWG 12 Conductors Spec 20-1 Solid Signal Cable
- Belden 601212 12 AWG 12 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601329 12 AWG 16 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601563 12 AWG 19 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601583 12 AWG 20 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601900 12 AWG 21 Conductors Spec 20-1 Stranded Signal Cable
- Belden 580106 12 AWG 25 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601540 10 AWG 2 Conductors Spec 20-1 Stranded Signal Cable
- Belden 581356 10 AWG 3 Conductors Spec 20-1 Solid Signal Cable
- Belden 601569 10 AWG 4 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601820 10 AWG 7 Conductors Spec 20-1 Stranded Signal Cable
- Belden 601605 8 AWG 2 Conductors Spec 20-1 Solid Signal Cable
- Belden 601430 8 AWG 2 Conductors Spec 20-1 Stranded Signal Cable
- Belden 603298 8 AWG 3 Conductors Spec 20-1 Stranded Signal Cable
- Belden 581710 8 AWG 7 Conductors Spec 20-1 Solid Signal Cable
Product Details
Belden offers a wide range of products for various municipal transportation applications: traffic communication, fire protective signal, data acquisition, inductance loop detection and traffic signal control.
Manufactured in ISO-certified facilities, Belden provides unsurpassed quality and reliability to ensure product consistency for every specification.
Features:
• Outdoor, moisture, and sunlight resistant for wet or dry locations
• Multiple standard conductor, insulation and jacket selections available
• Additional constructions available upon request
Benefits:
• Improved system uptime
• Improved protection against noise and unintended or outside signals
• Robust designs which meet or exceed International Municipal Signal Association (IMSA) specifications
Ground Wire:
• Ground Wire (Y/N): N
Insulation:
• Material: HDPE - High Density Polyethylene
• Wall Thickness (mm): 0.635
Outer Jacket:
• Material: LDPE - Low Density Polyethylene
• Nom. Wall Thickness (mm): 1.143
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Bulk Cable Weight: 60 lbs/1000 ft.
• Max. Recommended Pulling Tension: 150 lbs.
• Min. Bend Radius/Minor Axis: 3.600 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• IMSA Specification: 20-1
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
Suitability:
• Suitability - Outdoor: Yes
• Suitability - Aerial: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No