General Cable Armored Instrumentation Pairs Triads Individual and Overall Shield UL Type ITC-HL PLTC PVC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

General Cable Armored Instrumentation Pairs Triads Individual and Overall Shield UL Type ITC-HL PLTC PVC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Select gauge from drop-down menu for prices:

General Cable Armored Instrumentation Pairs Triads Individual and Overall Shield UL Type ITC-HL PLTC PVC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW®

Product Details

Conductor:
• Bare annealed copper per ASTM B3
• Class B stranding per ASTM B8

Insulation:
• Flame-retardant Polyvinyl Chloride(PVC), rated 105°C per UL Standards 13 and 2250
• Color-coded per ICEA Method 1: pairs – black and white; triads – black, white and red. Each conductor in each pair or triad is printed alphanumerically for easy identification

Shielded Pairs/Triads:
• Isolated and individually twisted pairs or triads with a Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, two sizes smaller than insulated conductors

Cable Assembly:
• Individually shielded pairs or triads and communication wire are cabled together with a left hand lay
• Communication wire: 22 AWG solid bare copper, flame-retardant Polyvinyl Chloride (PVC), rated 105°C, orange

Overall Shield:
• Flexfoil® aluminum/polyester tape shield providing 100% coverage
• Stranded tinned copper drain wire, same size as insulated conductors

Inner Jacket:
• Flame-retardant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C
• Nylon rip cord to facilitate jacketremoval

CCW Armor:
• Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1569
• CCW armor conductivity meets the grounding requirements of NEC Article 250

Overall Jacket:
• Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) per UL Standards 13 and 2250, black
• Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

Applications:
• CCW armored Instrumentation cables with individually shielded pairs or triads and an overall shield provide superior protection and reliability against physical damage for use in instrumentation and process control applications requiring ITC-HL or PLTC wiring methods where shielding against both external EMI and EMI between groups is required
• For use as Power Limited Tray Cable on circuits rated 150 V or less and 5 amps or less in Class 2 or Class 3 circuits in accordance with NEC Article 725
• For use as Instrumentation Tray Cable on circuits rated 150 V or less and 5 amps or less in accordance with NEC Article 727
• Recognized for use in Class I and III, Divisions 1 and 2; Class II, Division 2; or Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
• Installed indoors or outdoors, in wet or dry locations, in a raceway, as aerial cable on a messenger, in cable trays, or for direct burial
• Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

Features:
• CCW armor provides superior mechanical protection and an impervious barrier to moisture, gas and liquids
• CCW armor provides EMI shielding performance
• Meets cold impact at -40°C

Specifications:
Design Adherence:
• UL 13 Power-Limited Circuit Cables
• UL 2250 Instrumentation Tray Cable
• UL 1569 Metal Clad Cables
• UL 1309/CSA C22.2 No. 245 Marine Shipboard Cable

Flame Tests:
• ICEA T-29-520 (210,000 BTU/hr)
• IEEE 383 (70,000 BTU/hr)
• CSA FT4
• IEEE 1202 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEC 60332-3 Cat. A

Compliances:
• UL Type PLTC, SUN RES, DIR BUR, -40°C, UL File # E36118
• UL Type ITC-HL, UL File # E177408
• UL Listed Marine Shipboard, UL File # E85994
• American Bureau of Shipping (ABS) Listed for CWCMC
• RoHS Compliant

cond. Size (AWG) No. of pairs approximate Net weight General cable part number Action
Lbs/1000Ft Kg/Km
20 awg 7w (0.52 mm²) individual and overall shielded pairs
20 2 260 387 9250.20021221 Request a Quote
20 4 308 458 9250.20041221 Request a Quote
20 6 376 560 9250.20061221 Request a Quote
20 8 490 729 9250.20081221 Request a Quote
20 10 576 857 9250.20101221 Request a Quote
20 12 615 915 9250.20121221 Request a Quote
20 16 753 1,121 9250.20161221 Request a Quote
20 20 873 1,299 9250.20201221 Request a Quote
20 24 1,062 1,580 9250.20241221 Request a Quote
20 36 1,340 1,994 9250.20361221 Request a Quote
20 50 1,725 2,567 9250.20501221 Request a Quote
18 awg 7w (0.82 mm²) individual and overall shielded pairs
18 2 279 415 9250.18021221 Request a Quote
18 4 351 522 9250.18041221 Request a Quote
18 6 488 726 9250.18061221 Request a Quote
18 8 545 811 9250.18081221 Request a Quote
18 10 644 958 9250.18101221 Request a Quote
18 12 693 1,031 9250.18121221 Request a Quote
18 16 885 1,317 9250.18161221 Request a Quote
18 20 1,062 1,580 9250.18201221 Request a Quote
18 24 1,214 1,807 9250.18241221 Request a Quote
18 36 1,592 2,369 9250.18361221 Request a Quote
18 50 2,105 3,133 9250.18501221 Request a Quote
16 awg 7w (1.31 mm²) individual and overall shielded pairs
16 2 309 460 9250.16021221 Request a Quote
16 4 403 600 9250.16041221 Request a Quote
16 6 563 838 9250.16061221 Request a Quote
16 8 665 990 9250.16081221 Request a Quote
16 10 842 1,253 9250.16101221 Request a Quote
16 12 912 1,357 9250.16121221 Request a Quote
16 16 1,127 1,677 9250.16161221 Request a Quote
16 20 1,315 1,957 9250.16201221 Request a Quote
16 24 1,552 2,310 9250.16241221 Request a Quote
16 36 2,086 3,104 9250.16361221 Request a Quote
16 50 2,770 4,122 9250.16501221 Request a Quote

cond. Size (AWG) No. of pairs approximate Net weight General cable part number Action
Lbs/1000Ft Kg/Km
20 awg 7w (0.52 mm²) individual and overall shielded triads
20 4 358 533 9250.20041222 Request a Quote
20 8 557 829 9250.20081222 Request a Quote
20 12 761 1,132 9250.20121222 Request a Quote
20 16 906 1,348 9250.20161222 Request a Quote
20 24 1,287 1,915 9250.20241222 Request a Quote
20 36 1,674 2,491 9250.20361222 Request a Quote
18 awg 7w (0.82 mm²) individual and overall shielded triads
18 4 396 589 9250.18041222 Request a Quote
18 8 658 979 9250.18081222 Request a Quote
18 12 903 1,344 9250.18121222 Request a Quote
18 16 1,115 1,659 9250.18161222 Request a Quote
18 24 1,541 2,293 9250.18241222 Request a Quote
18 36 2,062 3,069 9250.18361222 Request a Quote
16 awg 7w (1.31 mm²) individual and overall shielded triads
16 4 530 789 9250.16041222 Request a Quote
16 8 780 1,161 9250.16081222 Request a Quote
16 12 1,144 1,702 9250.16121222 Request a Quote
16 16 1,378 2,051 9250.16161222 Request a Quote
16 24 1,973 2,936 9250.16241222 Request a Quote
16 36 2,729 4,061 9250.16361222 Request a Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question