Belden 18 AWG CSA Instrumentation 600V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x26 Cable

Belden 18 AWG CSA Instrumentation 600V ACIC Armored Individually and Overall Beldfoil Shielded Pairs 7x26 Cable

Product Details

Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.

Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.

Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance

Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.762

Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.128
• Inner Jacket Ripcord: Yes

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 15.494
• Outer Jacket Ripcord: Yes

Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum

Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Bulk Cable Weight: 154 lbs/1000 ft.
• Max. Recommended Pulling Tension: 57.400 lbs.
• Min. Bend Radius/Minor Axis: 7.300 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLABCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: Low Acid Test

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86 (18 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 14.7 (22 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.3
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 10.300 Ohm/1000 ft
• Max. Operating Voltage - Other: 600 (CEC ACIC)
• Max. Recommended Current: 2.5 Amps/Conductor @ 25°C

Flame Test:
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs belden cable
part number
Action
al. steel aluminum steel
18 18 1 24511 25506 Request A Quote
18 18 2 24512 25514 Request A Quote
18 18 4 24513 25503 Request A Quote
18 18 8 24514 25505 Request A Quote
18 18 12 24515 25501 Request A Quote
18 18 24 24520 25517 Request A Quote