General Cable GenSPEED® 10,000 Category 6A Cable Signal Strength and Power

General Cable GenSPEED® 10,000 Category 6A Cable Signal Strength and Power

Select gauge from drop-down menu for prices:

General Cable GenSPEED® 10,000 Category 6A Cable Signal Strength and Power

Product Details

Conductors : 23 AWG solid bare annealed copper 

Insulation 
• Non-Plenum: Polyolefin 
• Plenum: Fluoropolymer 

Color Code 
• Pair 1: Blue-White 
• Pair 2: Orange-White 
• Pair 3: Green-White 
• Pair 4: Brown-White 

Separator : T-Top cross-web 

Jacket 
• Non-Plenum: Flame-Retardant PVC 
• Plenum: Low-Smoke, Flame-Retardant PVC 

Features and Benefits 
• Extensive design development conducted to find the perfect blend of product performance and consistent manufacturability 
• Innovative T-Top cross-web provides superior internal electrical characteristics by locking the pairs into a systematic orientation within the cable 
• Superior flame and smoke characteristics achieved through innovative design and careful selection of materials with certified suppliers 
• TRU-Mark® print legend contains footage markings from 1000’ to 0’ 
• AirEs jacket provides superior flexibility and maximum separation of pairs from cable to cable for consistent PSANEXT and PSAACRF performance 
• Made in U.S.A. 

Applications 
• IEEE 802.3: 10G BASE-T, 1000 BASE-T, 100 BASE-TX, 10 BASE-T, PoE, PoE+ 
• ANSI/TIA 854: 1000 BASE-TX 
• Digital Video 
• Broadband and Baseband Analog Video 
• CDDI, Token Ring, ATM 

Standard Compliances 
• ANSI/TIA 568-C.2 
• NEC/CEC Type CMR (UL 1666) for Non-Plenum 
• NEC/CEC Type CMP (NFPA 262) for Plenum 
• UL 444 
• RoHS Compliant Directive 2011/65/EU 
• ANSI/TIA 862 (Building Automation) 
• ICEA S-116-732 
• ISO/IEC 11801 Ed. 2.0 (Class EA)

PHYSICAL DATA

cmr (non-plenum) cmp (plenum)
nominal cable diameter (in) 0.330 0.320
nominal cable weight (lbs/1000 ft) 42 45
minimum bend radius (in) 1.5 1.5
maximum pulling force (lbs) 40 40
temperature rating (?c)
installation:
operation:
0 to +60
-20 to +75
0 to +60
-20 to +75

PART NUMBERS
jacket color spool
cmr (non-plenum) cmp (plenum)
blue 7133819 7131819
white 7133820 7131820
yellow 7133822 7131822
gray 7133821 7131821
red 7133824 7131824
orange 7133826 7131826
green 7133823 7131823
black 7133828 7131828
pink 7133827 7131827
purple 7133825 7131825

ELECTRICAL PERFORMANCE
frequency
mhz

psacr*
(min)

acr*
(min)

insertion
loss
(max)

psnext
(min)

next
(min)

psacrf
(min)

acrf
(min)

return loss
(min)

tcl
(min)

psanext
(min)

psaacr
(min)
1 70.2 72.2 2.1 72.3 74.3 64.8 67.8 20.0 40.0 67.0 67.0
4 59.5 61.5 3.8 63.3 65.3 52.8 55.8 23.0 40.0 67.0 66.2
8 53.5 55.5 5.3 58.8 60.8 46.7 49.7 24.5 40.0 67.0 60.1
10 51.4 53.4 5.9 57.3 59.3 44.8 47.8 25.0 40.0 67.0 58.2
16 46.7 48.7 7.5 54.2 56.2 40.7 43.7 25.0 38.0 67.0 54.1
20 44.4 46.4 8.4 52.8 54.8 38.8 41.8 25.0 37.0 67.0 52.2
25 41.9 43.9 9.4 51.3 53.3 36.8 39.8 24.3 36.0 67.0 50.2
31.25 39.4 41.4 10.5 49.9 51.9 34.9 37.9 23.6 35.1 67.0 48.3
62.5 30.4 32.4 15.0 45.4 47.4 28.9 31.9 21.5 32.0 65.6 42.3
100 23.2 25.2 19.1 42.3 44.3 24.8 27.8 20.1 30.0 62.5 38.2
200 10.2 12.2 27.6 37.8 39.8 18.8 21.8 18.0 27.0 58.0 32.2
250 5.2 7.2 31.1 36.3 38.3 16.8 19.8 17.3 26.0 56.5 30.2
300 0.8 2.8 34.3 35.1 37.1 15.3 18.3 16.8 25.2 55.3 28.7
400 40.1 33.3 35.3 12.8 15.8 15.9 24.0 53.5 26.2
500 45.3 31.8 33.8 10.8 13.8 15.2 23.0 52.0 24.2

ELECTRICAL CHARACTERISTICS
max. nom.
dc resistance
ohms/100 m (328 ft) @ 20?c
9.38 7.50
dc resistance unbalance
individual pair %
4.00 < 1
delay skewns/100 m
45 30
nom. velocity of propagation
% speed of light
70
characteristic impedance
frequency (f): 1-500 mhz
ohms100 ± 15