Ultrol 60+ Cable
ULTROL 60+ Cable
An ULTROL CABLE is a flexible electrical cables made to facilitate instrumentation. ULTROL cables are best fits for measuring, regulation and control systems in the field of instrumentation and process control engineering. This is a special type of cable with a flexible copper conductor core in a galvanized braided wire to give a reliable protection against mechanical damages.
A conventional multi-strand ULTROL Cable is ideal in transmission of information on the state, the location and the operating conditions of the objects that ensure a give set up runs smoothly. They are extensively used to interconnect power cables and communication cables in a system.
With the daily evolving technology world over, the growth in the nuclear industry has continued to be immense. This in turn has seen the increase of nuclear cables in the electrical world. The nuclear industry is a very sensitive one that needs to be handled with utmost care and expertise. It is for this reason that only those cables and wires that meet the set internally recognized standards should be used. The cables ought to be durable, moisture resistant and flame retardant. There is a wide range of ULTROL 60+ cables and if one does not really understand the exact cable they require, they might as well go for a totally different cable that actually does not match their needs.
Nassau Electrical Supply is a supplier of a number of electrical cables and wires including ULTROL 60+. To find out more about these kinds of cables we have compiled the following information;
Construction
1.Conductor A conductor is a very important part of a cable. It actually is the cable in that it carries electric currents from one point to another. It is thus important that only the best of materials is used. Generally, ULTROL 60+ cables have conductors made of tinned annealed copper. Copper is a favorite material used as a conductor in most cables due to its ability to transfer electrical currents fast. It is also highly flexible, a feature which is often highly sort after in cables. This is to say that it easily bends and cuts in accordance to the needs and wants of the user.
Apart from its ability of having more electrical conductivity, tinned annealed copper has great anti- corrosion properties. This feature will ensure that your cable gives long term service. As you will soon find out, there are quite a number of ULTROL 60+ cables. Some of them are multi-conductors with various ranges of AWG.
2.Insulation Insulation is another important part of any other cable as it ensures the conductor is well protected from either physical or chemical damage. This is so as the life span of the cable may be extended for a range of time. It is thus vital that the insulation material be of great quality and outstanding features. For ULTROL 60+ cables, there are various kinds of insulation materials that have been used. This is because the different cables are used in different environments to perform different tasks. Some of the insulating materials used include;
a. Ethylene Propylene Rubber (EPR) - this is a synthetic elastomer with great thermal and electrical properties. With it, it only takes a very small cross- sectional area with the similar load carrying capacity. This kind of insulation is suitable for use in cables with very high voltages. It is for this reason that these kinds of cables are as well used in the application and installations in the mining industry. Because of the rubber insulation, these kinds of cables are known to be resistant to alkali substances, oxidation, acid, heat, water and weathering. During installation, cables with these kinds of insulation should be handled with care to avoid damage.
b.Cross linked Polyethylene (FR- XLPE)- this is a thermoset insulation material that is specially ideal for medium voltage applications. It is constructed using cross- linked polyethylene which transforms the thermoplastic material into a thermoset for better performance. This insulation material makes the cables to be resistant to radiation, moisture, chemical, heat and flame. The insulation is often done using base colors and tracers according to ICEA/ NEMA method 1.
3.Jacketing This is also very important in any cable because it protects both the conductor and the insulation. Just like the insulation, it also needs to be made of very good quality material. The ULTROL 60+ cables from Nassau Electrical Supply are jacketed using cross linked polyolefin (XLPO). This material can be used both as a jacketing material or an insulation material. One great thing with XLPO is that it is halogen free which is to say that it does not release gases when there is an exposure of fire. This jacketing material is sunlight resistant and can as well be used for direct burial on the ground. Thanks to the thermoset material you can be sure of circuit integrity. This is because it has great mechanical strength combined with excellent resistance to moisture, a number of chemicals and ozone. The jacketing material not only facilitates installation but also protects the cable from mechanical damage, chemical damage and moisture penetration.
Benefits of ULTROL 60+ Cable The ULTROL 60+ cable has a wide range of benefits and that is why it has continued to be used overtime in the nuclear world. As mentioned before, the conductor is made copper which is a highly flexible material making the cable bend and cut easily. The tinned annealed copper also makes the cable to be long lasting. This is because copper has anti- corrosion properties and is also high in conductivity. The insulation and jacketing materials have as well been uniquely designed to protect the cable against physical and chemical damage. The cable is also resistant to weather conditions, heat and moisture penetration thanks to the insulation and jacketing materials.
Approvals and Acceptance It is always wise to go for products that have been tested and proven safe by various bodies. This is good for both the user and the seller. As a seller, it creates confidence in your products and thus your customers will keep coming to you for any other issue. It is safe for the user in that it will not cause harm of any sort. The ULTROL 60+ cable has been proven safe as follows;
Canadian Standards Association 1.CSA Standard C22-2 No. 18, 174 2.MCA Series connectors approved for use with groups E, F and G of CEC Class II, division 1 3.Approved by CEC Ex’e’zone 4.Meets American Bureau of Shipping certifications 5.Approved bu UL 2225 standards for Class I Division 1 6.Listed for use in Hazardous locations 7.Class I - Division 2 - Groups A & B* 8.Class I - Division 2 - Groups C & D 9.Class II - Division 2 - Groups E, F & G 10.Class III 11.1/2 and 3/4 inch hub sizes 12.Canadian Standards Association Approved for use in hazardous locations
Specifications 1.Class I - Divisions 1 & 2 - Groups A, B, C & D 2.Class II - Divisions 1 & 2 - Groups E, F & G 3.Underwriters Laboratories 4.Listed for use in Hazardous locations 5.Class II - Division 2 - Groups E, F & G 6.Class III 7.1/2 and 3/4 inch hub sizes 8.Canadian Standards Association Approved for use in hazardous locations 9.Class I - Division 2 - Groups A & B* 10.Class I - Division 2 - Groups C & D 11.Class III 12.Meet the requirements for American Bureau of Shipping.
Types of ULTROL 60+ cables The market is flooded with a number of ULTROL 60+ cables. Nassau has the following inner their range;
1.416MC Series Rain Tight Connectors Non-Hazardous 2.416RA Series Rain Tight Connectors Non-Hazardous 3.424CU SERIES Explosion Proof Connectors Class I, Division 2 4.424MA Series Explosion Proof Connectors Class I, Division 1 5.424UN Series Explosion Proof Connectors Class I, Division 2 6.MCA Series Rain Tight Connectors Non-Hazardous 7.MCRA Series Rain Tight Connectors Non-Hazardous 8.MCXA Series Explosion Proof Connectors Class I, Division 1
Application The cables are often used in the nuclear industry. They are as well recommended for use in combined cycle units, in signal circuits, power generating plants and lighting controls. They are specially designed for use in critical circuits that require continuity of service. They could as well be used to provide connection between a cable tray and the device being used. In locations where only qualified professionals are required to service the installations the cables would be perfect for use as they are well labeled. Thanks to their superior protection, these cables can be applied where direct burial is needed.