Belden Cable Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Paired Cable

Belden Cable Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Paired Cable

Select gauge from drop-down menu for prices:

Belden Cable Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Paired Cable

Product Details

Belden® paired cable products are manufactured in a variety of gage sizes, dimensions, insulation materials, shielding configurations, and jacketing materials including Plenum and High-Temperature versions to meet the technical requirements of many different types of systems.

Paired cables allow balanced signal transmission, which results in lower crosstalk through common mode rejection. Due to the improved noise immunity of twisted pairs, they generally permit higher data speeds than multi-conductor cables.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1524

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Trade Name: Flamarrest®
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.3356

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +60°C
• Bulk Cable Weight: 11.906 Kg/Km
• Max. Recommended Pulling Tension: 71.171 N
• Min. Bend Radius/Minor Axis: 31.750 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (µH/m): 0.55777
• Nom. Capacitance Conductor to Conductor (pF/m): 101.711
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 193.579
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 79.0721
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 55.777
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.2 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Plenum Number: 88641
• Non-Plenum Number: 88641

awg # pairs overall cable-
nominal
dia. (mm)
belden cable
part
number
Action
24 1 2.692 82641 Request A Quote
24 2 4.115 82502 Request A Quote
24 3 4.293 82503 Request A Quote
24 4 4.902 82504 Request A Quote
24 5 4.978 82505 Request A Quote
24 6 5.309 82506 Request A Quote
24 9 6.248 82509 Request A Quote
24 1 2.692 88641 Request A Quote
24 3 4.445 89503 Request A Quote
24 4 4.877 89504 Request A Quote
24 5 5.004 89505 Request A Quote