Belden Cable Classic Premium 300% Ground Foil/Braid Design VFD Cable
Select gauge from drop-down menu for prices:
- Belden 29500 16 AWG 3C Classic Premium 300% Ground Foil/Braid Design VFD Cable
- Belden Cable 14 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29501
- Belden Cable 12 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29502
- Belden Cable 10 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29503
- Belden Cable 8 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29504
- Belden 29505 Cable 6 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable
- Belden Cable 4 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29506
- Belden Cable 2 AWG 3 Conductors Classic Premium 300% Ground Foil/Braid Design VFD Cable 29507
Product Details
Classic Foil/Braid Designs Features:
• High-strand conductors ease installation; enable better vibration resistance
• Full-sized insulated ground allows lower resistance path to ground
• Tinned copper conductors to prevent against corrosion
• Low capacitance and low impedance of the cables closely matches the drive and electrical values
• Round configuration for reliable sealing
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 300% ground four conductor
• Shielding: Foil + Braid
• Grounding: Full Size Insulated
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Tinned Copper
• Rating: 1000V UL Flexible Motor Supply
• 600V UL 1277 Type TC-ER
• 1000V UL 2277 Type WTTC
• 1000V CSA AWM I/II A/B FT4
• IEEE 1202
• UL Direct Burial
• XHHW-2, RHW-2 rated circuit conductors -14 AWG and larger
• 90°C Wet/Dry
• Suitable for Class I, II & III, Division 2 hazardous locations
• MSHA
• UL 1685 Vertical Tray Flame Test
• RoHS compliant
• CE approved
• C(UL) 600V Type CIC TC
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
awg | cond. stranding |
minimum bend radius |
belden cable part number |
Action | |
inch | mm | ||||
16 | 26 x 30 | 4.3 | 109.2 | 29500 | Request A Quote |
14 | 41 x 30 | 4.8 | 121.9 | 29501 | Request A Quote |
12 | 65 x 30 | 5.2 | 132.0 | 29502 | Request A Quote |
10 | 105 x 30 | 5.5 | 139.7 | 29503 | Request A Quote |
8 | 7 x 19 x 29 | 7.5 | 190.5 | 29504 | Request A Quote |
6 | 7 x 19 x 27 | 8.2 | 203.2 | 29505 | Request A Quote |
4 | 7 x 19 x 25 | 9.3 | 236.2 | 29506 | Request A Quote |
2 | 7 x 19 x 23 | 10.8 | 273.1 | 29507 | Request A Quote |