Prysmian and Draka Cable RadHard 62.5 / 125 μm Multimode Fibre Cable (MIL-PRF-49291/6)

Prysmian and Draka Cable RadHard 62.5 / 125 μm Multimode Fibre Cable (MIL-PRF-49291/6)

Select gauge from drop-down menu for prices:

Prysmian and Draka Cable RadHard 62.5 / 125 μm Multimode Fibre Cable (MIL-PRF-49291/6)

Product Details

This DrakaEliteTM RadHard 62.5 μm core diameter multimode fibre (MMF) can be used for high irradiative environments (e.g. gamma rays, X-flash, neutrons protons) up to a dose of about 10 kGy. For extreme irradiative environments (some MGy dose) DrakaEliteTM Super RadHard 50 μm core diameter MMF is recommended. Note: 1 Gy = 100 Rad.

This Germanium-doped 62.5 μm core diameter RadHard MMF has been qualified and approved by the U.S. Defense Supply Center, Columbus (DSCC) in accordance with the U.S. Military MIL-PRF-49291/6 specification.

Because Radiation Induced Attenuation (RIA) is a strong function of time after dose, dose rate, temperature, system operational wavelength, and system operational power, assessing the RIA performance of fibres should be conducted as close to conditions in the final application as possible.

The DrakaEliteTM 62.5 μm core diameter RadHard MMF can be used in all cable constructions, including loose tube, tight buffered, ribbon and central tube designs. This fibre complies with or exceeds IEC 60793-2-10 category A1b Optical Fibre Specification, TIA-492AAAA and Telcordia GR-20-Core.

Prysmian Group’ fibre plant Draka Comteq Fibre B.V. in Eindhoven , Netherlands, is MIL-STD-790 certified.

Features:
• RadHard behaviour
• Coated with the dual layer UV Acrylate

Advantages:
• Suitable for medium irradiative environments
• Optimized performance in tight-buffer cable applications

steady state gamma irradiation test conditions – mil 49291-6
temperature dose rate total dose
- 28°c / 25°c / 85°c 0.50 gy/s (sio2) classified

irradiation test requirements – mil 49291-6
max. induced
attenuation @1310nm
attenuation at
specified recovery time
specified recovery time
< 50 db/km
(total dose classified)
< 15 @ -28 °c
< 5 @ 25 °c
< 5 @ 85 °c
1000 s

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question